Final | 10/4/2011 | 10/4/2011 | 10/4/2011 | P | PASS |
Eric Strole
|
|
|
>> Inspection requested via web by Stephanie Brown
|
Final | 9/29/2011 | 9/30/2011 | 9/30/2011 | A | FAIL |
Eric Strole
|
|
|
>> Inspection requested via web by Stephanie Brown-1-Need air balance report on site. 2-Need approved manual j report on site. 3-Need dampers at registers for master bath and master closet. 4-Need to send cut sheet for dampers to be used at master bath and closet to troy james.
|
Rough-in | 9/2/2011 | 9/2/2011 | 9/2/2011 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Stephanie Brown-rough-in pass. do not final till troy james approves dampers at registers.
|
Rough-in | 8/31/2011 | 9/1/2011 | 9/1/2011 | P | FAIL |
Eric Strole
|
|
|
Please meet at the job at 1:00 pm for duct blaster witness. Phone #: ###-#### >> Inspection requested via web by Stephanie Brown-20 lb gas test pass, duct blast test pass, rough-in not installed per approved manual j report. need to resubmit manual j or install per manual j report on site.
|
Rough-in | 8/30/2011 | 8/31/2011 | 8/31/2011 | P | FAIL |
Eric Strole
|
|
|
3:30 to witness blasting. Scott will meet you at jobsite please contact him @ ###-#### if there should be a problem and to confirm the time please. >> Inspection requested via web by Stephanie Brown-gas test, duct blast test fail, need to fix range exhaust in over head.
|