Final | 7/26/2013 | 7/26/2013 | 7/26/2013 | P | PASS |
Dixie Fellows
|
|
|
oleg ###-####
|
Conference | 7/26/2013 | 7/26/2013 | 7/26/2013 | P | PASS |
Dixie Fellows
|
|
|
oleg Phone #: ###-####...c/n fixed
|
Final | 7/8/2013 | 7/9/2013 | 7/9/2013 | A | FAIL |
Dixie Fellows
|
|
|
Ollie-please call first Phone #: ###-####...COMB AIR TERMINATION NOT PER MANUF
|
Rough-in | 4/24/2013 | 4/24/2013 | 4/24/2013 | P | PASS |
Dixie Fellows
|
|
|
oleg Phone #: ###-####...r/i ok..20lb gas ok..duct blaster ok
|
Rough-in | 4/22/2013 | 4/22/2013 | 4/23/2013 | P | FAIL |
Dixie Fellows
|
|
|
oleg ###-####....need 6" outside air duct tied into r/a in hallway
|
Rough-in | 4/19/2013 | 4/19/2013 | 4/19/2013 | P | FAIL |
Bill VanDegrift
|
|
|
oleg please call 1 hr before going out Phone #: ###-#### everything looks ok just needs damper on outside air into return box on 1st floor hall
|
Pressure Test | 4/18/2013 | 4/18/2013 | 4/18/2013 | P | PASS |
Dixie Fellows
|
|
|
oleg Phone #: ###-####...20LB GAS OK
|
Rough-in | 4/18/2013 | 4/18/2013 | 4/18/2013 | P | FAIL |
Dixie Fellows
|
|
|
oleg Phone #: ###-####...NEED APPROVED MANUAL J ON SITE...NEED TO SHIELD HORIZ SECTION OF W/H FLUE...NEED NAIL PLATE AT DRYER VENT..NEED 6' FRESH AIR WITH A DAMPER ..DAMPERS TO BE IN ALL SUPPLY DUCTS
|