Permit Information
Permit NumberMEC13-05469
StatusExpired
Name PARAMOUNT HEATING & A/C INC
Site Address 526 E ORION CT
Project Name 
Customer Number 
ePlanReviewNo
Description
Mechanical Permit - New: radiant floor heat, HVAC
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Mec-Aging Inspection7/17/20197/17/20197/17/2019PCANC
DetailsBen Livingston
DOC - Permit Expired7/17/20197/17/20197/17/2019PPASS
DetailsBen Livingston
Mec-Aging Inspection6/4/20196/4/20196/4/2019 CANC
DetailsBen Livingston
no new hvac being done
Mec-Aging Inspection3/5/20193/5/20193/5/2019 CANC
DetailsBen Livingston
Final12/4/201812/5/201812/5/2018AFAIL
DetailsBen Livingston
Items that remain for Final:
Set 5 ton condencer on south east corner
all work for outdoor kitchen under this permit will need to be complette, nothing for the out door kitchen has been started yet.
Garage unit heater not installed will need combustion air because of tight construction.
Furnace in garage that serves the kitchen needs condensate piping ran, and filter access addressed.
All missing grilles and thermostates on all floors need to be installed,
Range vent and cook top need to be installed, makeup air for range provided by RTU economizers preset partial open, air balance will show proper fresh air value.
Need Balance and Blast report.
Fan needs to be installed in downstairs furnace room.Duct seal and 2nd condensate drain on furnace.
1st furnace in crawl needs 2nd condensate drain ran. 2nd furnace needs both condensates ran.
Conference12/4/201812/5/201812/5/2018ADONE
DetailsChad Schwendiman
10 AM - Met at home with contractor. There will potentialy be a new contrator taking over the mechanical install to finish out the house, so we met to document what's not completed and still needs to be done to achieve a mechanical final. Refrence Ben Livingston's notes on 12/5/18 for items needed to complete house.
Mec-Aging Inspection10/23/201810/23/201810/23/2018 CANC
DetailsBen Livingston
Mec-Aging Inspection7/24/20187/24/20187/24/2018 CANC
DetailsBen Livingston
Mec-Aging Inspection4/24/20184/24/20184/24/2018 CANC
DetailsBen Livingston
Mec-Aging Inspection1/23/20181/23/20181/23/2018 CANC
DetailsEric Strole
Mec-Aging Inspection10/24/201710/24/201710/24/2017 PEND
DetailsBen Livingston
Mec-Aging Inspection7/25/20177/25/20177/25/2017 CANC
DetailsBen Livingston
Mec-Aging Inspection4/25/20174/25/20174/25/2017 CANC
DetailsBen Livingston
Mec-Aging Inspection1/24/20171/24/20171/24/2017 PEND
DetailsBill VanDegrift
I talked to the contractor and he said they were still working on this project and will call it in when they are ready for a final.
Mec-Aging Inspection10/25/201610/25/201610/25/2016 PEND
DetailsBen Livingston
Mec-Aging Inspection7/26/20167/26/20167/26/2016 PEND
DetailsBen Livingston
still working
Mec-Aging Inspection4/26/20164/26/20164/26/2016 PEND
DetailsBen Livingston
still working on project.
Rough-in1/26/20161/27/20161/27/2016APASS
DetailsEric Strole
Need to check return air behind fire place on main floor. Please call Aaron with any questions Phone #: ###-#### Inspection requested via web by john shay
Mec-Aging Inspection12/16/201512/16/201512/16/2015 PART
DetailsBill VanDegrift
no calls
Rough-in9/16/20159/16/20159/16/2015PPART
DetailsDixie Fellows
11 BATHROOMS OK..ALL DRYER VENTS AND RANGE EXHAUST OK...60 LB AND 20LB GAS TESTS OK
Rough-in9/14/20159/15/20159/15/2015ACANC
DetailsEric Strole
Hi Dixie, just give me a call when your ready! Thanks and have a great day. Phone #: ###-#### >> Inspection requested via web by john shay Inspection cancelled from web by: john shay
Pressure Test9/1/20159/2/20159/2/2015PPASS
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by john shay..2---100lb hrdronic tests ok
Pressure Test8/19/20158/20/20158/20/2015APART
DetailsEric Strole
Hi Dixie this is Aaron we are just doing a pressure test on part of the floor heat so they can cover the floor. I''ll give you a call this morning and meet you there! Thank You!!! Phone #: ###-#### Inspection requested via web by john shay-OK to cover 2nd flr radiant heating. Test ok.
Mec-Aging Inspection6/17/20156/17/20156/17/2015 PASS
DetailsDixie Fellows
WORK IN PROGRESS
Pressure Test12/26/201312/27/201312/27/2013APASS
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by john shay...100lb test on all hydronics in basement ok