Mec-Aging Inspection | 7/17/2019 | 7/17/2019 | 7/17/2019 | P | CANC |
Ben Livingston
|
|
|
|
DOC - Permit Expired | 7/17/2019 | 7/17/2019 | 7/17/2019 | P | PASS |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 6/4/2019 | 6/4/2019 | 6/4/2019 | | CANC |
Ben Livingston
|
|
|
no new hvac being done
|
Mec-Aging Inspection | 3/5/2019 | 3/5/2019 | 3/5/2019 | | CANC |
Ben Livingston
|
|
|
|
Final | 12/4/2018 | 12/5/2018 | 12/5/2018 | A | FAIL |
Ben Livingston
|
|
|
Items that remain for Final: Set 5 ton condencer on south east corner all work for outdoor kitchen under this permit will need to be complette, nothing for the out door kitchen has been started yet. Garage unit heater not installed will need combustion air because of tight construction. Furnace in garage that serves the kitchen needs condensate piping ran, and filter access addressed. All missing grilles and thermostates on all floors need to be installed, Range vent and cook top need to be installed, makeup air for range provided by RTU economizers preset partial open, air balance will show proper fresh air value. Need Balance and Blast report. Fan needs to be installed in downstairs furnace room.Duct seal and 2nd condensate drain on furnace. 1st furnace in crawl needs 2nd condensate drain ran. 2nd furnace needs both condensates ran.
|
Conference | 12/4/2018 | 12/5/2018 | 12/5/2018 | A | DONE |
Chad Schwendiman
|
|
|
10 AM - Met at home with contractor. There will potentialy be a new contrator taking over the mechanical install to finish out the house, so we met to document what's not completed and still needs to be done to achieve a mechanical final. Refrence Ben Livingston's notes on 12/5/18 for items needed to complete house.
|
Mec-Aging Inspection | 10/23/2018 | 10/23/2018 | 10/23/2018 | | CANC |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 7/24/2018 | 7/24/2018 | 7/24/2018 | | CANC |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 4/24/2018 | 4/24/2018 | 4/24/2018 | | CANC |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 1/23/2018 | 1/23/2018 | 1/23/2018 | | CANC |
Eric Strole
|
|
|
|
Mec-Aging Inspection | 10/24/2017 | 10/24/2017 | 10/24/2017 | | PEND |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 7/25/2017 | 7/25/2017 | 7/25/2017 | | CANC |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 4/25/2017 | 4/25/2017 | 4/25/2017 | | CANC |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 1/24/2017 | 1/24/2017 | 1/24/2017 | | PEND |
Bill VanDegrift
|
|
|
I talked to the contractor and he said they were still working on this project and will call it in when they are ready for a final.
|
Mec-Aging Inspection | 10/25/2016 | 10/25/2016 | 10/25/2016 | | PEND |
Ben Livingston
|
|
|
|
Mec-Aging Inspection | 7/26/2016 | 7/26/2016 | 7/26/2016 | | PEND |
Ben Livingston
|
|
|
still working
|
Mec-Aging Inspection | 4/26/2016 | 4/26/2016 | 4/26/2016 | | PEND |
Ben Livingston
|
|
|
still working on project.
|
Rough-in | 1/26/2016 | 1/27/2016 | 1/27/2016 | A | PASS |
Eric Strole
|
|
|
Need to check return air behind fire place on main floor. Please call Aaron with any questions Phone #: ###-#### Inspection requested via web by john shay
|
Mec-Aging Inspection | 12/16/2015 | 12/16/2015 | 12/16/2015 | | PART |
Bill VanDegrift
|
|
|
no calls
|
Rough-in | 9/16/2015 | 9/16/2015 | 9/16/2015 | P | PART |
Dixie Fellows
|
|
|
11 BATHROOMS OK..ALL DRYER VENTS AND RANGE EXHAUST OK...60 LB AND 20LB GAS TESTS OK
|
Rough-in | 9/14/2015 | 9/15/2015 | 9/15/2015 | A | CANC |
Eric Strole
|
|
|
Hi Dixie, just give me a call when your ready! Thanks and have a great day. Phone #: ###-#### >> Inspection requested via web by john shay Inspection cancelled from web by: john shay
|
Pressure Test | 9/1/2015 | 9/2/2015 | 9/2/2015 | P | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by john shay..2---100lb hrdronic tests ok
|
Pressure Test | 8/19/2015 | 8/20/2015 | 8/20/2015 | A | PART |
Eric Strole
|
|
|
Hi Dixie this is Aaron we are just doing a pressure test on part of the floor heat so they can cover the floor. I''ll give you a call this morning and meet you there! Thank You!!! Phone #: ###-#### Inspection requested via web by john shay-OK to cover 2nd flr radiant heating. Test ok.
|
Mec-Aging Inspection | 6/17/2015 | 6/17/2015 | 6/17/2015 | | PASS |
Dixie Fellows
|
|
|
WORK IN PROGRESS
|
Pressure Test | 12/26/2013 | 12/27/2013 | 12/27/2013 | A | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by john shay...100lb test on all hydronics in basement ok
|