Permit Information
Permit NumberMEC14-02639
StatusFinaled
Name VINCEN MECHANICAL
Site Address 1911 N 31ST ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Mechanical Permit - New: New construction, install new furnace and a/c, vent two dryers. Gas piping to furnace, water heater and fireplace (not installing fireplace)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/20/201410/21/201410/21/2014APASS
DetailsEric Strole
The final inspection is just for the water heater. It was not approved last final inspection and it has been replaced with a new one. Phone #: ###-#### Inspection requested via web by Krista Boss
Final10/10/201410/10/201410/10/2014PFAIL
DetailsDixie Fellows
Taylor Phone #: ###-####..w/h b-vent to be 2' higher than any vertical wall within 8'..need comb air for w/h
Final10/9/201410/9/201410/9/2014PCANC
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
Final10/8/201410/9/201410/9/2014ACANC
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
Final10/7/201410/8/201410/8/2014PCANC
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
Rough-in7/15/20147/16/20147/16/2014PPASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Krista Boss
Pressure Test7/14/20147/15/20147/15/2014PPASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Krista Boss-20 lb gas test pass
Rough-in7/14/20147/15/20147/15/2014PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Krista Boss-Need transfer grills, need to hook up supply 2nd flr bedroom, need to insulate Y in attic space, need 6" fresh air to the return with a damper and need to run condensate to an approved location.
Pressure Test7/11/20147/14/20147/14/2014AFAIL
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by Krista Boss..leak
Rough-in7/11/20147/14/20147/14/2014AFAIL
DetailsDixie Fellows
Phone #: ###-#### >> Inspection requested via web by Krista Boss..no manual j on site..no fl/p installed..need nail plates at all duct drops between studs..strap bath exhaust at 2nd floor..
Rough-in7/10/20147/10/20147/10/2014PPART
DetailsAlan Hauser
Please scheduled Alan Houser for a partial. Identification #350. Alan already knows about this and has agreed to do the inspection. Thank you!! all duct that is to be covered by insulation is ok for cover, not done in attic or between 1st and 2nd floors. STILL NEED GAS PRESSURE TEST, GUAGE AT WATER HEATER 1ST FLOOR
Pressure Test7/10/20147/10/20147/10/2014PNR
DetailsAlan Hauser
Please scheduled Alan Houser for a partial. Identification #350. Alan already knows about this and has agreed to do the inspection. Thank you!! no test on gas piping, piping in walls is ok, just need test later