Final | 10/20/2014 | 10/21/2014 | 10/21/2014 | A | PASS |
Eric Strole
|
|
|
The final inspection is just for the water heater. It was not approved last final inspection and it has been replaced with a new one. Phone #: ###-#### Inspection requested via web by Krista Boss
|
Final | 10/10/2014 | 10/10/2014 | 10/10/2014 | P | FAIL |
Dixie Fellows
|
|
|
Taylor Phone #: ###-####..w/h b-vent to be 2' higher than any vertical wall within 8'..need comb air for w/h
|
Final | 10/9/2014 | 10/9/2014 | 10/9/2014 | P | CANC |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|
Final | 10/8/2014 | 10/9/2014 | 10/9/2014 | A | CANC |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|
Final | 10/7/2014 | 10/8/2014 | 10/8/2014 | P | CANC |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|
Rough-in | 7/15/2014 | 7/16/2014 | 7/16/2014 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss
|
Pressure Test | 7/14/2014 | 7/15/2014 | 7/15/2014 | P | PASS |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss-20 lb gas test pass
|
Rough-in | 7/14/2014 | 7/15/2014 | 7/15/2014 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss-Need transfer grills, need to hook up supply 2nd flr bedroom, need to insulate Y in attic space, need 6" fresh air to the return with a damper and need to run condensate to an approved location.
|
Pressure Test | 7/11/2014 | 7/14/2014 | 7/14/2014 | A | FAIL |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss..leak
|
Rough-in | 7/11/2014 | 7/14/2014 | 7/14/2014 | A | FAIL |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss..no manual j on site..no fl/p installed..need nail plates at all duct drops between studs..strap bath exhaust at 2nd floor..
|
Rough-in | 7/10/2014 | 7/10/2014 | 7/10/2014 | P | PART |
Alan Hauser
|
|
|
Please scheduled Alan Houser for a partial. Identification #350. Alan already knows about this and has agreed to do the inspection. Thank you!! all duct that is to be covered by insulation is ok for cover, not done in attic or between 1st and 2nd floors. STILL NEED GAS PRESSURE TEST, GUAGE AT WATER HEATER 1ST FLOOR
|
Pressure Test | 7/10/2014 | 7/10/2014 | 7/10/2014 | P | NR |
Alan Hauser
|
|
|
Please scheduled Alan Houser for a partial. Identification #350. Alan already knows about this and has agreed to do the inspection. Thank you!! no test on gas piping, piping in walls is ok, just need test later
|