Final | 5/12/2015 | 5/13/2015 | 5/13/2015 | A | PASS |
Alan Hauser
|
|
|
|
Final | 5/11/2015 | 5/12/2015 | 5/12/2015 | P | FAIL |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart..NO AIR BALANCE REPORT ON SITE
|
Rough-in | 4/6/2015 | 4/7/2015 | 4/7/2015 | A | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart
|
Rough-in | 4/3/2015 | 4/6/2015 | 4/6/2015 | A | FAIL |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart...OUTSIDE AIR MUST TIE INTO R/A PLENUM UPSTREAM OF THE FILTER WITH AN ACCESSIBLE BACK DRAFT DAMPER ...NEED TO SLEEVE B-VENT IN ATTIC AND NEED 1" CLEARANCE AT ROOF..BATH EXHAUST TO BE 3' FROM OPEN WINDOW..MOVE SUPPLY RUN IN GREAT ROOM ABOVE THE ELEC CORD OR IT WILL GET SMASHED BY THE SHEETROCK
|
Pressure Test | 4/3/2015 | 4/6/2015 | 4/6/2015 | A | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart..20lb gas ok
|
Pressure Test | 4/2/2015 | 4/3/2015 | 4/3/2015 | A | CANC |
Chad Schwendiman
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Rough-in | 4/2/2015 | 4/3/2015 | 4/3/2015 | A | CANC |
Chad Schwendiman
|
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|