Permit Information
Permit NumberMEC16-00164
StatusFinaled
Name SUPREME HEATING & COOLING INC
Site Address 9012 W STEVE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Hvac on new construction
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/17/20163/18/20163/18/2016PPASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Arcadio Martinez
Rough-in1/18/20161/19/20161/19/2016APASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Arcadio Martinez- 20lb gas, 5lb flue, rough in
Rough-in1/13/20161/14/20161/14/2016AFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Arcadio Martinez-dryer vent needs nail plate at floor penetration. bvent needs 1 inch clearance from insulation shield, romex needs to move. main floor return not per manual s. pressure gauges on both gas and flue dont zero out.