Permit Information
Permit NumberMEC16-03692
StatusFinaled
Name ADVANCED HEATING & COOLING
Site Address 500 S CAPITOL BLVD Unit: 100
Project Name 
Customer Number 
ePlanReviewNo
Description
New: 1 - lot of zero clearance grease duct, fittings, clean outs, 1 - inline supply fan that serves dining area, 1 - ceiling mounted exhaust fan that serves restroom, 1 - duct heater, installation of KC supplied hood exhaust fans and indoor air handling unit,
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/8/20172/9/20172/9/2017APASS
DetailsChad Schwendiman
Final inspection request. Please contact job lead, Larry, ###-####, with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
Final12/16/201612/19/201612/19/2016APART
DetailsChad Schwendiman
Request for final inspection. Please contact Casey ###-#### or Larry ###-#### with any questions or concerns Phone #: ###-#### Inspection requested via web by Heather Gransbery - Okay for 10 restruant workers to occupy the restruant.
Final12/14/201612/15/201612/15/2016PFAIL
DetailsChad Schwendiman
Request for Final inspection. Please contact Larry, ###-####, or Jerry, ###-####, with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
1) Need hinges installed on exhaust fans
2) Need 1500 deg gasket installed on exhaust fans.
3) Need grease traps installed on exhaust fans
4) Curbs for exhaust fans need to be vented.
5) Need to extend the discharge on the exhaust fans above the wall
6) Need engineers approval for relocation of filter section on MUA
7) Need 18" clearance to combustables from Class 1 hood
Rough-in12/2/201612/5/201612/5/2016PPART
DetailsChad Schwendiman
Inspection request for grid. Please contact job lead, Larry, with any questions or concerns. ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery - okay to cover grid ceiling
Rough-in11/16/201611/16/201611/16/2016PPASS
DetailsBen Livingston
Request for light inspection for grease duct. Please contact lead, Casey, ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
Rough-in11/14/201611/15/201611/15/2016PPART
DetailsChad Schwendiman
Request for cover inspection and light test on grease duct. Please contact job lead, Larry, ###-####, with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - light test pass on the north hood duct connection
Rough-in10/24/201610/24/201610/24/2016PPART
DetailsChad Schwendiman
Inspection request for partial cover. Contact Larry ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - Okay to cover hard lid in richards
Rough-in10/7/201610/7/201610/7/2016PCANC
DetailsChad Schwendiman
Cover inspection request for 2nd floor. Please contact job lead, Larry Halbert, with any questions or concerns. ###-#### Phone #: ###-#### >> Inspection requested via web by Heather Gransbery Inspection cancelled from web by: Heather Gransbery
Rough-in9/27/20169/28/20169/28/2016APART
DetailsChad Schwendiman
Cover inspection request 3rd Fl Myrtle side of building. Please contact job lead Larry Halbert ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - okay to cover 3rd floor myrtle side of the building
Rough-in9/22/20169/23/20169/23/2016PFAIL
DetailsChad Schwendiman
Cover inspection request, 2nd floor Capital side of the building. Cover inspection request for 3rd floor Myrtle side of building. Please contact job lead Larry Halbert, ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - need to complete ducting, need to fix fire caulking on fresh air ducts, need to adjust duct mounted access doors to where they are accessable
Rough-in9/12/20169/12/20169/12/2016PCANC
DetailsChad Schwendiman
R/I inspection for cover 2nd floor Myrtle St. side of the building. Please contact job lead Larry Halbert ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery - this is the wrong permit