Permit Information
Permit NumberMEC16-04135
StatusFinaled
Name PAIGE MECHANICAL GROUP INC
Site Address 1505 S BROADWAY AVE
Project Name 
Customer Number16.6439
ePlanReviewNo
Description
Alteration: Install owner provided equipment, new duct work, and grease duct.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Conference10/20/201610/20/201610/20/2016ADONE
DetailsBrian Scoles
Meet on Job to go over kitchen equipment under class 1 hoods
Final10/19/201610/20/201610/20/2016APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Nicholas Paige
Final10/13/201610/14/201610/14/2016AFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Nicholas Paige - Need air balance report for class 1 hoods, all equipment needs to be in place under the hoods to verify clearances, Exhuast and flues need to terminate 10' away or 3' above fresh air intakes
Rough-in10/3/201610/4/201610/4/2016APASS
DetailsChad Schwendiman
please call ernie with any questions Phone #: ###-#### Inspection requested via web by Nicholas Paige - okay to cover ceilings
Rough-in9/28/20169/29/20169/29/2016APART
DetailsChad Schwendiman
Fire Wrap Phone #: ###-#### Inspection requested via web by Nicholas Paige - 1st layer pass
Rough-in9/28/20169/28/20169/28/2016PPASS
DetailsChad Schwendiman
grease duct Phone #: ###-#### Inspection requested via web by Nicholas Paige
Rough-in9/26/20169/28/20169/28/2016APART
DetailsChad Schwendiman
please give john a call
a cover/Grease duct inspection Phone #: ###-#### Inspection requested via web by Nicholas Paige - light test okay. need to have 1/4" per foot slope on horizontal grease duct. need to reschedule to check slope once corrected