Final | 1/12/2017 | 1/13/2017 | 1/13/2017 | A | PASS |
Brian Scoles
|
|
|
Inspection requested via web by Matthew Grant
|
Final | 1/11/2017 | 1/12/2017 | 1/12/2017 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Matthew Grant- need uv protection on lines set outdoors- need armor flex finished at coil- need to hook up wiring for a/c to furnace-water heater needs flue complete, trim ring and gas line finished- 4" duct in furnace closet 90 degree broken at ceiling level- range duct needs completed to hood- need register installed in laundry room upstairs- need supply, return and outsode air insulated in furnace closet
|
Rough-in | 11/15/2016 | 11/15/2016 | 11/15/2016 | P | PASS |
Ben Livingston
|
|
|
Inspection requested via web by Matthew Grant
|
Pressure Test | 11/15/2016 | 11/15/2016 | 11/15/2016 | P | PASS |
Ben Livingston
|
|
|
Inspection requested via web by Matthew Grant 20lb gas,5lb flue
|
Pressure Test | 11/10/2016 | 11/14/2016 | 11/14/2016 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Matthew Grant-Gas gauge will not zero out. Test on flue fail.
|
Rough-in | 11/10/2016 | 11/14/2016 | 11/14/2016 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### Inspection requested via web by Matthew Grant-Insulation sheild requires a 1" clearance around B-vent. 8" fresh air needs to come off the return air plenum.
|