Final | 1/26/2017 | 1/27/2017 | 1/27/2017 | A | PASS |
Ben Livingston
|
|
|
Inspection requested via web by Lori Dille
|
Conference | 1/9/2017 | 1/10/2017 | 1/10/2017 | P | DONE |
Chad Schwendiman
|
|
|
1pm - met at home with Air balancer to try to see why the system is low on air in the sun room. After looking at the install it appears as though the way the system was installed is causing exess back pressure on the barametric bypass damper causing the air to short cycle through the unit. relocating the location the 10" supply to the sun room at the supply plenum box should allow for more air to get to the sun room and relieve the exess back pressure.
|
Conference | 1/9/2017 | 1/10/2017 | 1/10/2017 | P | PART |
Bill VanDegrift
|
|
|
1 pm meet with Ben, Chad and Rubin, reduct sunroom trunk, set ac unit.
|
Final | 1/10/2017 | 1/10/2017 | 1/10/2017 | P | FAIL |
Ben Livingston
|
|
|
Jamie Phone #: ###-#### need condenser set for final
|
Final | 1/5/2017 | 1/5/2017 | 1/5/2017 | P | PART |
Bill VanDegrift
|
|
|
Jamie Phone #: ###-####-needs mech final so can have building final which is PM today as well-Ben asked that we schedule to you since he can't get down the road due to snow. needs to review balance report. light in the sunroom
|
Final | 1/4/2017 | 1/4/2017 | 1/4/2017 | P | CANC |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by Lori Dille please rescedual, road needs to be plowed
|
Final | 11/9/2016 | 11/9/2016 | 11/9/2016 | P | NR |
Ben Livingston
|
|
|
Gas line was existing call Jayme if you have any questions ###-#### Inspection requested via web by Lori Dille
|
Rough-in | 11/9/2016 | 11/9/2016 | 11/9/2016 | P | PASS |
Ben Livingston
|
|
|
Gas line was existing call Jayme if you have any questions ###-#### Inspection requested via web by Lori Dille 5lb flue rough in
|
Final | 11/4/2016 | 11/4/2016 | 11/4/2016 | P | CANC |
Ben Livingston
|
|
|
Replaced existing system and ductwork due to smoke damage Phone #: ###-#### >> Inspection requested via web by Lori Dille ******BUILDING PERMIT IS NOT ISSUED****
|