Permit Information
Permit NumberMEC17-01386
StatusFinaled
Name KAMM SCOTT B
Site Address 3527 W ROSE HILL ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC system
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/10/20194/10/20194/10/2019PPASS
DetailsJack Reynolds
Kamm Phone #: ###-####
- final ok
Mec-Request for Extension2/4/20192/4/20192/4/2019PPASS
DetailsChad Schwendiman
Mec-Aging Inspection2/1/20192/1/20192/1/2019 DONE
DetailsJack Reynolds
WIP
Rough-in11/2/201811/2/201811/2/2018PPART
DetailsJack Reynolds
Scott Phone #: ###-####- mini split in the laundry room R/I ok- check outdoor unit for level on next R/I
Rough-in9/25/20189/26/20189/26/2018APART
DetailsJack Reynolds
Scott Phone #: ###-####- dryer vent ok- water heater flue clearances ok- condensate for north first floor mini split ok- exhaust fan on south ok
Rough-in9/17/20189/17/20189/17/2018PFAIL
DetailsJack Reynolds
Scott Phone #: ###-####- dryer vent needs to be smooth pipe- water heater needs 3" clearances on horizantal runs and 1" clearances on vertical- condensates need to be finished- there is also two more ductless splits that need installed for R/I cover-southside still has an exhaust fan that needs vented and a ductless split that needs condensate finished- need to look into the HVAC contractors permit for the multiport ductless that is finished-
Mec-Aging Inspection8/13/20188/13/20188/13/2018 DONE
DetailsJack Reynolds
wip
Mec-Aging Inspection5/14/20185/14/20185/14/2018 CANC
DetailsChad Schwendiman
wip
Pressure Test2/12/20182/13/20182/13/2018APASS
DetailsChad Schwendiman
Scott Phone #: ###-#### - 20lb gas pass
Pressure Test2/6/20182/6/20182/6/2018PFAIL
DetailsChad Schwendiman
Scott Phone #: ###-#### - Not holding pressure
Conference11/8/201711/8/201711/8/2017PPASS
DetailsBen Livingston
Scott Phone #: ###-####
Rough-in8/28/20178/28/20178/28/2017PPASS
DetailsChad Schwendiman
Scott Phone #: ###-#### - range vent
Rough-in8/17/20178/17/20178/17/2017PPASS
DetailsBrian Scoles
Scott Phone #: ###-####- ex fans ok
Pressure Test8/16/20178/16/20178/16/2017PPASS
DetailsChad Schwendiman
Scott Phone #: ###-#### - 20lb gas pass
Rough-in8/16/20178/16/20178/16/2017PFAIL
DetailsChad Schwendiman
Scott Phone #: ###-#### - Need to use approved panduit straps or metal cinch bands
Conference4/17/20174/17/20174/17/2017PDONE
DetailsChad Schwendiman
Scott Phone #: ###-#### - meet onsite with contractor to go over the installation