New: Install 1 each rooftop install ceiling exhaust fans, Install kitchen hood controls grilles registers ductwork insulation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/10/20177/11/20177/10/2017APASS
DetailsEric Strole
Final needed at Ranch Market Coffee A.M. inspection preferred. Phone #: ###-#### Inspection requested via web by Karl Hestekin
Final7/5/20177/5/20177/5/2017PPART
DetailsChad Schwendiman
Final inspection needed for Ranch Market Coffee if you need to speak to someone contact Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin - Temp Occupancy okay. Still need a 30" wide clear access for servicing AHU
Final7/2/20177/3/20177/3/2017PFAIL
DetailsEric Strole
Need pm final inspection Ranch Market coffee Phone #: ###-#### Inspection requested via web by Karl Hestekin-Need access at packaged unit, Need p-trap at rtu. Need firewrap at grease duct above hood and need balance report.
Final7/3/20177/3/20177/3/2017PFAIL
DetailsChad Schwendiman
Need pm final inspection Ranch Market coffee Phone #: ###-#### Inspection requested via web by Karl Hestekin - Need clear service access for rtu, need p-trap on rtu, need to fire wrap grease duct hood connection, need a copy of air balance report
Final6/30/20177/3/20177/3/2017ACANC
DetailsChad Schwendiman
Final inspection needed for Ranch Market coffee am preferred if you have any questions contact Karl ###-#### Phone #: ###-#### >> Inspection requested via web by Karl Hestekin Inspection cancelled from web by: Karl Hestekin
Rough-in6/29/20176/30/20176/30/2017PNR
DetailsEric Strole
Need a 2nd layer Fire Wrap inspection. please contact Karl at ###-#### at the Ranch Market Coffee thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin-Not done, will check on final.
Rough-in6/29/20176/30/20176/30/2017APART
DetailsEric Strole
Need a 1st layer Fire Wrap inspection for 9:00 Am. please contact Karl at ###-#### Phone #: ###-#### Inspection requested via web by Karl Hestekin-1st layer fire wrap pass.
Rough-in6/28/20176/29/20176/29/2017PDONE
DetailsEric Strole
Can I please get a grease duct inspection for Ranch Market Coffee P.M. needed to ensure that the project is ready for the inspection can reach Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin-Conferance on grease duct
Rough-in6/28/20176/29/20176/29/2017PPART
DetailsBen Livingston
Can I please get a grease duct inspection for Ranch Market Coffee P.M. needed to ensure that the project is ready for the inspection can reach Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin
conf. on grease duct cleanouts done
Conference6/23/20176/26/20176/26/2017ADONE
DetailsEric Strole
Need a conference with the inspector Monday A.M. With Rob # ###-#### if unable to reach Rob Call Karl at ###-#### This is for Ranch market Coffee thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin-Conferance on grease duct.
Conference6/26/20176/26/20176/26/2017APASS
DetailsBen Livingston
A.M. With Rob # ###-#### if unable to reach Rob Call Karl at ###-#### This is for Ranch market Coffee thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin
Rough-in5/10/20175/10/20175/10/2017PPART
DetailsBen Livingston
Mechanical Cover inspection PM needed if unable to be a P.m inspection if unable to do a P.M. inspection please call Karl and we will request an inspection for the 11th will not be ready until P.M. thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin
hard lids and walls okay, need to work out clearence issue with grease duct louver, mech mes. not ready
Rough-in5/9/20175/10/20175/10/2017PPART
DetailsEric Strole
Mechanical Cover inspection PM needed if unable to be a P.m inspection if unable to do a P.M. inspection please call Karl and we will request an inspection for the 11th will not be ready until P.M. thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin-OK to cover walls and ceilings except mezzanine and fireplace area where gas piping needs repiped.Need to address clearance issues on grease duct exhaust.