Mec-Aging Inspection | 7/9/2018 | 7/9/2018 | 7/9/2018 | | CANC |
Ben Livingston
|
|
|
|
DOC - Permit Finaled | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Ben Livingston
|
|
|
|
Pressure Test | 10/25/2017 | 10/26/2017 | 10/26/2017 | P | PASS |
Ben Livingston
|
|
|
Please call when you are on the way. We would also appreciate the latest call of the day if possible. Phone #: ###-#### Inspection requested via web by Dan McFate 5lb flue
|
Conference | 10/20/2017 | 10/20/2017 | 10/20/2017 | P | DONE |
Brian Scoles
|
|
|
Call before you come so we can meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Dan McFate- discussed putting 90% furnace in existing location of electric furnace- gas there for water heater just need to veryify BTU to both appliances and sizing can be met- need R/A in side wall- combustion air high and low already there for water heater- exhaust and intake for furnace will come from roof- access needed big enough to remove appliance- make sure clearances are met per furnace manufactures installation manual- provide CO detectors if none are installed- condensate can go to floor drain in closet by water heater
|