Permit Information
Permit NumberMEC18-00137
StatusFinaled
Name ICON AIR
Site Address 2728 N COOLWATER AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: HVAC Installation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/28/20183/1/20183/1/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
Final2/26/20182/27/20182/27/2018ANR
DetailsBrian Scoles
Also Blast witness.
Will have them there set up and ready to blast at 9:30 Phone #: ###-#### Inspection requested via web by Randy Hart- needs line set hooked up- flue to water heater- line set uv taped outside and hole thru foundation closed off- not ready for final
Conference2/27/20182/27/20182/27/2018APASS
DetailsBrian Scoles
Also Blast witness.
Will have them there set up and ready to blast at 9:30 Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass- 97 cfm loss
Rough-in1/11/20181/12/20181/12/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok- will need to witness duct blast test
Rough-in1/11/20181/11/20181/11/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- corrections not made- need crawl ducting complete for rough in inspection and dryer vent needs supported every 4 feet-
Rough-in1/9/20181/9/20181/9/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- dryer vent exhaust exceeds 35'/ reroute or add booster fan or show submittal of dryer being installed can handle the length- crawl needs complete to do inspection- need inert tape on gas line penetrating garage wall at meter location- left correction notice front window
Pressure Test1/9/20181/9/20181/9/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass