Final | 7/26/2018 | 7/27/2018 | 7/26/2018 | A | PASS |
Chad Schwendiman
|
|
|
Final inspection Contact Stan Lillquist ###-#### Pictures were emailed to Chad and Jack. Phone #: ###-#### Inspection requested via web by Dan Flaherty
|
Final | 7/24/2018 | 7/25/2018 | 7/25/2018 | A | FAIL |
Chad Schwendiman
|
|
|
Final inspection, Contact Stan Lillquist ###-#### TAB report will email. Phone #: ###-#### Inspection requested via web by Dan Flaherty - Still need supports on the EVAP. section of the make up air units
|
Final | 6/21/2018 | 6/21/2018 | 6/21/2018 | P | PART |
Chad Schwendiman
|
|
|
Final Inspection ; Antonio is your contact. Phone #: ###-#### Inspection requested via web by Kim Adams - Temporary occupancy okay. Need service protection rails in place on condensor with in 10' of the edge of the roof, Need grease trays installed on all grease fans, Need proper supports under evap sections of MUA's, Need completed air balance report.
|
Conference | 6/14/2018 | 6/14/2018 | 6/14/2018 | P | PEND |
Ben Livingston
|
|
|
Conference ; Mike Beason is your contact. Phone #: ###-#### Inspection requested via web by Kim Adams
|
Rough-in | 6/11/2018 | 6/11/2018 | 6/11/2018 | P | PASS |
Chad Schwendiman
|
|
|
rough in inspection ; Antonio is your contact. Phone #: ###-#### Inspection requested via web by Kim Adams - bakery ceiling okay to cover
|
Rough-in | 6/6/2018 | 6/7/2018 | 6/7/2018 | A | PASS |
Brian Scoles
|
|
|
rough in inspection for duct insulation . Tyson is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- firewrap ok- ok to install ceiling tiles
|
Rough-in | 6/5/2018 | 6/7/2018 | 6/6/2018 | A | CANC |
Chad Schwendiman
|
|
|
Rough in inspection for duct insulation - Antonio is your contact. Thank you! Phone #: ###-#### >> Inspection requested via web by Kim Adams Inspection cancelled from web by: Kim Adams
|
Rough-in | 5/31/2018 | 6/1/2018 | 6/1/2018 | A | PASS |
Chad Schwendiman
|
|
|
light test . Dave Dechambeau contact, Phone #: ###-#### - Light test pass for left kitchen hood
|
Rough-in | 5/30/2018 | 5/31/2018 | 5/31/2018 | P | CANC |
Chad Schwendiman
|
|
|
light test . Dave Dechambeau contact, Phone #: ###-#### Inspection requested via web by Kim Adams
|
Rough-in | 5/29/2018 | 5/30/2018 | 5/30/2018 | A | PASS |
Chad Schwendiman
|
|
|
light test inspection. Dave Dechambeau is your contact Phone #: ###-#### Inspection requested via web by Kim Adams - Light test pass for right kitchen hood
|
Rough-in | 5/24/2018 | 5/25/2018 | 5/25/2018 | A | PASS |
Ben Livingston
|
|
|
Grease duct light test. Contact Dave DeChambeau ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty tie in fittings grease duct deli 1 gease duct for kitchen left and right
|
Rough-in | 5/23/2018 | 5/24/2018 | 5/24/2018 | P | PASS |
Chad Schwendiman
|
|
|
Grease duct light test Contact Dave DeChambeau ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Light test pass for wood burner
|
Rough-in | 5/23/2018 | 5/24/2018 | 5/24/2018 | A | PASS |
Chad Schwendiman
|
|
|
rough in inspection for above the ceiling Phone #: ###-#### Inspection requested via web by Kim Adams - okay to cover ceilings in mezzanine, and pharmacy
|
Rough-in | 5/21/2018 | 5/21/2018 | 5/21/2018 | P | PASS |
Chad Schwendiman
|
|
|
Light test for meat smoker - Dave Dechambeau is your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams
|
Rough-in | 5/17/2018 | 5/18/2018 | 5/18/2018 | A | PASS |
Ben Livingston
|
|
|
Grease duct light test on Deli Hood # 2 ; Meat Island Hood. Contact Dave DeChambeau ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty meat island and deli. 2 grease duct ok
|
Rough-in | 5/14/2018 | 5/15/2018 | 5/15/2018 | A | PASS |
Chad Schwendiman
|
|
|
Rough in for Roof duct Contact Antonio ###-#### Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Okay to insulate all the duct on the roof.
|
Rough-in | 5/11/2018 | 5/14/2018 | 5/14/2018 | A | FAIL |
Chad Schwendiman
|
|
|
Rough in for Roof duct Contact Antonio ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Need to finish sealing the 4th system
|
Rough-in | 5/10/2018 | 5/11/2018 | 5/11/2018 | P | PASS |
Chad Schwendiman
|
|
|
Grease duct light test at TML 120 E 40th. Contact Steve Beason ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Light test pass
|
Rough-in | 5/11/2018 | 5/11/2018 | 5/11/2018 | P | PASS |
Chad Schwendiman
|
|
|
Okay to insulate ducts on roof for AC-6, 14, & 15.
|
Rough-in | 5/10/2018 | 5/11/2018 | 5/11/2018 | A | PASS |
Chad Schwendiman
|
|
|
Grease duct light test at Albertsons job site. Contact Dave DeChambeau ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Light test pass for bakery hood
|
Conference | 5/9/2018 | 5/10/2018 | 5/10/2018 | P | DONE |
Chad Schwendiman
|
|
|
Light test grease duct. Contact is Steve here at TML officer on 120 E 40th St. Phone #: ###-#### Inspection requested via web by Kim Adams
|
Conference | 5/9/2018 | 5/10/2018 | 5/9/2018 | A | CANC |
Chad Schwendiman
|
|
|
Grease duct light test at TML 102 E 40th. Contact Steve Beason ###-#### Phone #: ###-#### >> Inspection requested via web by Dan Flaherty Inspection cancelled from web by: Kim Adams
|
Conference | 4/30/2018 | 4/30/2018 | 4/30/2018 | P | PASS |
Chad Schwendiman
|
|
|
At TML shop 120 E 40th street Grease duct light test. Contact Steve Beason ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Light test pass on 8ea. 10' drops with transitions
|
Rough-in | 4/23/2018 | 4/23/2018 | 4/23/2018 | P | PASS |
Chad Schwendiman
|
|
|
Rough in Inspection ; Antonio is your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams - duct work in pharmacy okay
|
Rough-in | 4/19/2018 | 4/19/2018 | 4/19/2018 | P | PASS |
Chad Schwendiman
|
|
|
inspection for the front entry and the bakery. Antonio will be your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams
|
Rough-in | 4/11/2018 | 4/11/2018 | 4/11/2018 | P | PASS |
Chad Schwendiman
|
|
|
rough in inspection for the mezzanine - Antonio is your contact Phone #: ###-#### Inspection requested via web by Kim Adams - Duct seal okay on duct work in, and below mezannine
|
Rough-in | 4/2/2018 | 4/2/2018 | 4/2/2018 | P | PART |
Chad Schwendiman
|
|
|
Rough In Inspection for Hard lids. Antonio will be your contact. Phone #: ###-#### Inspection requested via web by Kim Adams - Okay to cover hard lids in bathrooms in the north east corner of building.
|