Permit Information
Permit NumberMEC18-00565
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 1424 W FRONT ST
Project Name 
Customer Number4127
ePlanReviewNo
Description
New: furnace a/c,baht ven,dr vent,hood vent,t stat,d/ work,gas pipe
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/27/20186/27/20186/27/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak
Card not on site to sign6/27/20186/27/20186/27/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak
Final6/19/20186/20/20186/20/2018AFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - ladder needs to extend up to roof to gain access to roof for inspection
Final6/18/20186/18/20186/18/2018PFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - No access to roof to verify corrections have been made. (ladder has been removed)
Final6/15/20186/15/20186/15/2018PFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - Corrections from 6-14-18 have not been done. In addition missing dryer vent termination on unit 101, need UV protection on linesets, need to install vent caps on roof
Final6/13/20186/14/20186/14/2018PFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Oleg Chervak
water heater flue not connected, water heater not connected to gas, cannot use 2 gas flex connectorsback to back
Rough-in2/25/20182/26/20182/26/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak
Rough-in2/22/20182/23/20182/23/2018AFAIL
DetailsChad Schwendiman
LATE AM PLZ CALL 208 412 4919 Phone #: ###-#### Inspection requested via web by Oleg Chervak - Missing transfer in bedroom in unit d, missing insulation shield in unit e, Duct not sized per manual j in unit h
Rough-in2/21/20182/21/20182/21/2018PFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - Still need the new approved manual J's onsite
Pressure Test2/16/20182/16/20182/16/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - 20lb gas pass for all units, 5lb flue pass for all units
Rough-in2/16/20182/16/20182/16/2018PCANC
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak
Rough-in2/15/20182/15/20182/15/2018PCANC
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - New manual J's not approved yet
Rough-in2/13/20182/13/20182/13/2018PFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak -
Fresh air not per approved manual J's
Ducts not sized per appoved manual J's
Missing insulation shield on b-vent
Insulation shields need 1" gap from b-vent
dryers over 35' in length
Crawls not complete
flue pressure not done on ground floor units
Range vents?
Pressure Test2/13/20182/13/20182/13/2018PPART
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - 20lb gas pass units B, H. Flue pressure pass units D, E, F, G, H. Gas fail unit G. flue pressure fail units A, B, C.
Pressure Test2/6/20182/6/20182/6/2018PPART
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak - 20lb gas pass for units A, C, D, E, F, 20lb gas fail for units B, G, H. Still need to pressure test pvc flues
Rough-in2/6/20182/6/20182/6/2018PNR
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Oleg Chervak