Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberMEC18-01516
StatusFinaled
Name EASY HEATING & AIR
Site Address 1068 N VINE ST
Project Name 
Customer Number1002
ePlanReviewNo
Description
Complete HVAC Installation: Residential New Construction HVAC System
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/11/20191/11/20191/11/2019PPASS
DetailsBen Livingston
Mira Phone #: ###-####
Final12/26/201812/26/201812/26/2018PFAIL
DetailsBen Livingston
Call one hour prior to arrival - gates are locked.// Mira Piva Phone #: ###-####
need blast test and air palance report
Rough-in7/23/20187/24/20187/24/2018APASS
DetailsBen Livingston
Gate codes are 1092, 6445 Phone #: ###-#### Inspection requested via web by kelly Martin
Rough-in7/16/20187/17/20187/17/2018AFAIL
DetailsBen Livingston
Call Kelly Martin for Rough In. Fans are installed over garage Phone #: ###-#### Inspection requested via web by kelly Martin
flex coming off exhaust fans radius is way to short, vynl flex tubing for mini split is not approved condensate material
Rough-in7/5/20187/5/20187/5/2018PFAIL
DetailsBen Livingston
Gate codes are 1092 and 6445 Phone #: ###-#### Inspection requested via web by kelly Martin
fan in bonus room bath room needs to be run to out side
Pressure Test7/5/20187/5/20187/5/2018PPASS
DetailsBen Livingston
Gate codes are 1092 and 6445 Phone #: ###-#### Inspection requested via web by kelly Martin
20lb gas 5lb flue x3 okay
Rough-in7/2/20187/2/20187/2/2018PCANC
DetailsBen Livingston
gate codes are 1092 and 6445 Phone #: ###-#### Inspection requested via web by kelly Martin
canc. per contractor
Pressure Test7/2/20187/2/20187/2/2018PCANC
DetailsBen Livingston
code for gate locks - 1092 and 6445
Phone #: ###-#### Inspection requested via web by kelly Martin
Rough-in6/28/20186/28/20186/28/2018PFAIL
DetailsBen Livingston
Mira Piva is homeowner and is the contact for this inspection. Kelly Buel is lead installer for this job, if you see something and would like to talk with him, his number is ###-#### Phone #: ###-#### Inspection requested via web by kelly Martin
upstaires dryer vent need nail plate, need approved manual J on site for roughin inspection
Pressure Test6/28/20186/28/20186/28/2018PFAIL
DetailsBen Livingston
Mira Piva is homeowner and is the contact for this inspection. Kelly Buel is lead installer for this job, if you see something and would like to talk with him, his number is ###-#### Phone #: ###-#### Inspection requested via web by kelly Martin
flue x3 under 5lb, gas pressure at 10lb