Final | 10/10/2018 | 10/11/2018 | 10/11/2018 | A | PASS |
Jack Reynolds
|
|
|
Please call the builder Brett Ogata at ###-#### one half hour before going so he can meet you there to let you in. If he doesn''t answer, leave a message or text him, thanks. Inspection requested via web by 4 Seasons - final ok
|
Final | 10/9/2018 | 10/10/2018 | 10/10/2018 | A | NH |
Jack Reynolds
|
|
|
Please call Brett at ###-#### a half hour before so he can meet you there, thanks. Inspection requested via web by 4 Seasons - no access to home
|
Rough-in | 5/8/2018 | 5/9/2018 | 5/9/2018 | P | PASS |
Jack Reynolds
|
|
|
Please do a rough-in and pressure test. Lock box code is 5234 if no one is there. Call James at ###-#### with any questions, thanks. Inspection requested via web by 4 Seasons - will need to see make up air for range vent at final- 20 lb gas test ok- fireplace R/I ok- range vent ok
|
Rough-in | 5/7/2018 | 5/7/2018 | 5/7/2018 | P | FAIL |
Jack Reynolds
|
|
|
Please do a rough-in and pressure test. If you have any questions, call James at ###-####, thanks. Inspection requested via web by 4 Seasons- sheet rock holes behind fireplace need patched- need non combustible material 6.5 inches above fireplace- range hood is over 400 cfm so it needs make up air interlocked to match range hood cfm- 20lb gas failed need shut off valve to open ended tee to another shut off valve followed by gasline with 20 lb pressure test- also need to support gas line in crawl space
|