Final | 12/11/2018 | 12/12/2018 | 12/12/2018 | A | PASS |
Ben Livingston
|
|
|
Access 5296 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
|
Final | 12/10/2018 | 12/10/2018 | 12/10/2018 | P | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN water heater needs combustion air
|
Rough-in | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
|
Rough-in | 6/28/2018 | 6/28/2018 | 6/28/2018 | P | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN rough in corrections not made
|
Pressure Test | 6/28/2018 | 6/28/2018 | 6/28/2018 | P | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN 5lb flue x2 20 lb gas and piping okay
|
Pressure Test | 6/26/2018 | 6/26/2018 | 6/26/2018 | P | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN need to use approved stricker plates, gas flex cannot be attatched to wall studs per installation instructions,fittings not installed per manufacturers installation instruction
|
Rough-in | 6/26/2018 | 6/26/2018 | 6/26/2018 | P | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN bedrooms in basement need return path, floor boots in basement need to be sealed to the floor,
|