Permit Information
Permit NumberMEC18-02618
StatusFinaled
Name A-1 HEATING & AIR CONDITIONING
Site Address 3531 W HILLCREST DR
Project Name 
Customer NumberNovak
ePlanReviewNo
Description
Alteration or Repair: Replace furnace and AC. Duct to new addition. Vent bath fan. R4180623
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/14/201812/14/201812/14/2018PPASS
DetailsJack Reynolds
Inspector aware of situation and is communicating with Tyrel Inspection requested via web by Arielle Hendricks
- 5lb flue pressure test
-gas piping size for furnace ok
Final12/12/201812/12/201812/12/2018PFAIL
DetailsJack Reynolds
Larren ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- need to prove 1/2" gas line is big enough for furnace
- need to flue test
Final11/19/201811/21/201811/21/2018PCANC
DetailsJack Reynolds
Please call on way: Tyrel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks-
Pressure Test11/19/201811/21/201811/21/2018PCANC
DetailsJack Reynolds
Please call on way: Tyrel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- not sure what needed to be pressure tested on this site
Pressure Test11/19/201811/20/201811/19/2018PCANC
DetailsJack Reynolds
Please call on way: Tyrel ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
Rough-in10/3/201810/9/201810/9/2018APASS
DetailsJack Reynolds
Please call the customer when on way: Larren Novak ###-####
We had a partial pass on the last Rough-In because we needed a Blast and Flue Test. The Blast has been done, the Flue Test will be ready when we FINAL the job. Phone #: ###-#### Inspection requested via web by Krista Boss- duct blast ok- still need to prove 1/2" gas line is big enough for the furnace- flue test will be done at final- will want to see dryer vent box sealed at final
Rough-in10/2/201810/2/201810/2/2018PPART
DetailsTroy James
Would like early PM and call on way. Phone #: ###-#### Inspection requested via web by Xanti Berria
ok to cover new addition only, need duct blast test, flue test and prove the 1/2" to furnace is big enough, need test to flue
Pressure Test10/2/201810/2/201810/2/2018PCANC
DetailsJack Reynolds
Would like early PM and call on way Phone #: ###-#### >> Inspection requested via web by Xanti Berria Inspection cancelled from web by: Xanti Berria
Final10/2/201810/2/201810/2/2018PCANC
DetailsJack Reynolds
Would like early PM Phone #: ###-#### >> Inspection requested via web by Xanti Berria Inspection cancelled from web by: Xanti Berria
Rough-in7/13/20187/16/20187/16/2018APART
DetailsJack Reynolds
Please call on way: Larren ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- man J ok- supply ducting in crawl space ok- return ducting in attic ok-
Rough-in7/10/20187/10/20187/10/2018PCANC
DetailsJack Reynolds
Late PM. We are fixing this today in the afternoon, so please call before arrival: Gener ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
Rough-in7/9/20187/10/20187/9/2018ACANC
DetailsJack Reynolds
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
Rough-in7/9/20187/9/20187/9/2018PFAIL
DetailsJack Reynolds
Please call on way: Darrius ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- flex ducting is being smash by floor joistes- need to have an approved Man J.
Rough-in6/15/20186/15/20186/15/2018PCANC
DetailsJack Reynolds
ok to pour concrete - please call Brett ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss