Final | 7/20/2018 | 7/23/2018 | 7/23/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kaila Martarano- corrections made- furnace a/c coil co ok
|
Final | 6/7/2018 | 6/8/2018 | 6/8/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kaila Martarano- need uv protection on linset- need weather tite whip from disconnect to a/c- need drip leg on gas line between shut valve and furnace- need to provide CO detectors- need to seal lineset penetration outside and have arma flex thru foundation- need to secure flexable conduit to wall at furnace location- need to cap off b vent where rmoved from existing b vent flue
|