Final | 6/12/2018 | 6/12/2018 | 6/12/2018 | A | PASS |
Jack Reynolds
|
|
|
Jim is contractor call for access if no one is on site. Reinspection with corrections. Phone #: ###-#### Inspection requested via web by Scott Sparrell- 20lb gas pressure test pass- penetration sealed ok
|
Pressure Test | 6/11/2018 | 6/11/2018 | 6/11/2018 | A | FAIL |
Jack Reynolds
|
|
|
Contact is Jim of Expeditor. He has access to building to witness test. Phone #: ###-#### Inspection requested via web by Scott Sparrell - test gauge was under 20 lb- need open tee between the two shut off valves- need inert tape where gas line penetrates foundation and needs to be sealed
|