Final | 10/1/2018 | 10/2/2018 | 10/2/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart
|
Rough-in | 9/27/2018 | 9/27/2018 | 9/27/2018 | P | CANC |
Brian Scoles
|
|
|
|
Pressure Test | 9/27/2018 | 9/27/2018 | 9/27/2018 | P | PASS |
Brian Scoles
|
|
|
20lb gas was passed on 7-31-18- went by and tagged meter per contractor request- please have general leave R/I sticker for mechanical in window until gas is set
|
Conference | 9/27/2018 | 9/28/2018 | 9/27/2018 | A | CANC |
Brian Scoles
|
|
|
Please place pressure pass sticker on gas pipe. cannot get meter set Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
Final | 9/20/2018 | 9/24/2018 | 9/24/2018 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- no access- gas pipe penetration needs sealed
|
Final | 9/18/2018 | 9/19/2018 | 9/19/2018 | A | FAIL |
Brian Scoles
|
|
|
Final Fire Place Final Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need to seal gas line penetration at meter location- need to hook up gas flexes to furnace and water heater and fire off- secondary drain off coil need to discharge to concrete need to add 45 degree fitting runs onto wood now- dryer penetration in laundry room needs sealed off open to wood structure- range hood needs finished and sealed- fireplace needs gas hooked up- left correction notice on side of furnace
|
Conference | 8/7/2018 | 8/8/2018 | 8/8/2018 | A | PASS |
Brian Scoles
|
|
|
Blast witness @ 11:30 Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass
|
Rough-in | 7/31/2018 | 8/1/2018 | 8/1/2018 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
|
Rough-in | 7/30/2018 | 7/31/2018 | 7/31/2018 | A | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need to seal exhaust fan where bare metal ties onto plastic fitting on fan
|
Pressure Test | 7/30/2018 | 7/31/2018 | 7/31/2018 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
|