Permit Information
Permit NumberMEC18-03826
StatusFinaled
Name THE HEATING AND COOLING COMPANY
Site Address 919 N HAINES ST
Project NameGalinato fire repair
Customer Number 
ePlanReviewNo
Description
Complete new hvac system due to fire
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/23/201810/23/201810/23/2018PPASS
DetailsBen Livingston
Preston Phone #: ###-####
Final10/19/201810/19/201810/19/2018PFAIL
DetailsBen Livingston
Presten Phone #: ###-####
need balance report, line set needs more uv tape
Rough-in8/8/20188/9/20188/9/2018PPASS
DetailsBen Livingston
Preston Phone #: ###-####
Pressure Test8/6/20188/7/20188/7/2018APASS
DetailsBen Livingston
Preston Phone #: ###-####
20lb gas, 5lb flue
Rough-in8/6/20188/7/20188/7/2018AFAIL
DetailsBen Livingston
Preston Phone #: ###-####
crawl needs to be complete, gas pipe buy furnace needs a nail plate, dryer vent needs to be 4" diamiter wall needs to be furred out, need approved manual J need 6" fresh air