Permit Information
Permit NumberMEC18-04193
StatusExpired
Name TVR INC
Site Address 1624 E MELODY ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: carrier gas furnace, ac, coil, relocate gas line
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Mec-Aging Inspection7/23/20197/23/20197/23/2019 PASS
DetailsJack Reynolds
Expired ok
DOC - Permit Expired7/23/20197/23/20197/23/2019APASS
DetailsJack Reynolds
Doc Permit Expired ok
Mec-Aging Inspection4/23/20194/23/20194/23/2019 DONE
DetailsJack Reynolds
called TVR and talked with Brandon about their mechanical aging permit. Add duct work to permit and reschedule. Permit will expire in 180 days if not active
Final9/18/20189/18/20189/18/2018PFAIL
DetailsJack Reynolds
Final - call RJ 30 minutes before arrival Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pressure test ok- wet switch ok- co detectors ok- lineset penetration ok- electrical conduit for A/C ok-
- need to add other to permit for duct work in addition
Final9/4/20189/5/20189/5/2018AFAIL
DetailsJack Reynolds
final - call RJ 1/2 hour before inspection so we can have someone on-site Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- need to see a 20lb gas pressure test on gas line- line set needs insulation installed through wall penetration and sealed- need to install wet switch on secoundary- home needs co detectors installed near bedrooms- electrical contractor needs to run weather tight conduit for A/C disconnect- add other to permit for new duct work