Final | 11/2/2018 | 11/2/2018 | 11/2/2018 | P | PASS |
Jack Reynolds
|
|
|
Fireplace & HVAC, call for garage code - Oleg Phone #: ###-####- final ok
|
Final | 11/1/2018 | 11/1/2018 | 11/1/2018 | P | NH |
Jack Reynolds
|
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak - no access to new home and no codes for garage
|
Final | 10/30/2018 | 10/31/2018 | 10/31/2018 | A | FAIL |
Jack Reynolds
|
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak - need city approved Man J onsite- need a ductblast performed and documentation onsite- line set insulation at furnace needs repaired
|
Rough-in | 9/20/2018 | 9/20/2018 | 9/20/2018 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20 lb gas test ok- fireplace R/I ok- HVAC R/I ok
|
Rough-in | 9/19/2018 | 9/19/2018 | 9/19/2018 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- crawl not finished- need to seal all exhaust fans connections
|
Rough-in | 9/17/2018 | 9/17/2018 | 9/17/2018 | P | FAIL |
Jack Reynolds
|
|
|
mec and firepl Phone #: ###-#### Inspection requested via web by Oleg Chervak - line set has rip in the insulation at the top of the wall -supply trunk in the attic needs insulated -crawl not finished -insulation sheild in the attic for the water heater need to be centered around the pipe to maintain 1" clearances -fire caulk around fireplace vent needs to be sealed -fresh air for the furnace is terminating out the soffit and will need a fire damper or terminate side wall( WUI Zone A) - flex runs need to be installed per Manuf. spec the inner liner needs to be taped and the outer liner needs to be zip tied. One of the flex runs for an exhaust fan was not connected and not sealed with tape
|
Pressure Test | 9/17/2018 | 9/17/2018 | 9/17/2018 | P | PASS |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pressure test ok
|