Permit Information
Permit NumberMEC18-04507
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 7633 S WAGONS WEST AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: furn ac bath dr hood
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/2/201811/2/201811/2/2018PPASS
DetailsJack Reynolds
Fireplace & HVAC, call for garage code - Oleg Phone #: ###-####- final ok
Final11/1/201811/1/201811/1/2018PNH
DetailsJack Reynolds
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
- no access to new home and no codes for garage
Final10/30/201810/31/201810/31/2018AFAIL
DetailsJack Reynolds
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
- need city approved Man J onsite- need a ductblast performed and documentation onsite- line set insulation at furnace needs repaired
Rough-in9/20/20189/20/20189/20/2018PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20 lb gas test ok- fireplace R/I ok- HVAC R/I ok
Rough-in9/19/20189/19/20189/19/2018PFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Oleg Chervak- crawl not finished- need to seal all exhaust fans connections
Rough-in9/17/20189/17/20189/17/2018PFAIL
DetailsJack Reynolds
mec and firepl Phone #: ###-#### Inspection requested via web by Oleg Chervak
- line set has rip in the insulation at the top of the wall
-supply trunk in the attic needs insulated
-crawl not finished
-insulation sheild in the attic for the water heater need to be centered around the pipe to maintain 1" clearances
-fire caulk around fireplace vent needs to be sealed
-fresh air for the furnace is terminating out the soffit and will need a fire damper or terminate side wall( WUI Zone A)
- flex runs need to be installed per Manuf. spec the inner liner needs to be taped and the outer liner needs to be zip tied. One of the flex runs for an exhaust fan was not connected and not sealed with tape
Pressure Test9/17/20189/17/20189/17/2018PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pressure test ok