Permit Information
Permit NumberMEC18-04613
StatusFinaled
Name TEP INC
Site Address 2712 S SIMSBURY PL
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Installation of (1) 60,000 BTU gas furnace, (1) condenser, (1) fireplace, gas piping, bath fans with venting, supply and return ducting and diffusers.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/12/201812/13/201812/13/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- final ok
Rough-in10/2/201810/3/201810/3/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- R/I ok- look at equipment on final inspection not set yet- man j with prints
Rough-in10/3/201810/3/201810/3/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- fireplace R/I ok
Pressure Test10/3/201810/3/201810/3/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- 20lb gas pass- 5lb flue pass
Rough-in9/28/201810/1/201810/1/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- gas test failed- need approved manual J onsite- need approved csst nail plates- need to insulate bare metal R/A square to round in attic- crawls needs completed- dryer vent needs nail plates at ceiling and seal dryer duct to termination box- left correction notice front window
Pressure Test9/28/201810/1/201810/1/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Tim Petsche- gauge at 4 psi