Permit Information
Permit NumberMEC18-04793
StatusFinaled
Name TVR INC
Site Address 6411 W PRIMROSE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Split system, ductless split, fireplace, gas piping, GRD''s, exhaust systems, ductwork
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/22/20192/25/20192/25/2019APASS
DetailsBrian Scoles
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- HVAC and fireplace final ok
Final2/18/20192/19/20192/19/2019PFAIL
DetailsBrian Scoles
final re-insection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need sediment trap on unit heater gas piping between shutoff valve and appliance- mantel height needs to be addressed Dave looking into this
Final2/12/20192/13/20192/13/2019AFAIL
DetailsBrian Scoles
final - garage code #9604 Phone #: ###-#### Inspection requested via web by Brandon Sorensen- mantel height to low per manufactures installation instructions need to move up- 2nd drain needs ran or wet switch instlled- pvc furnace flue needs clearance to combustibles unit heat fluing- R/A needs insulated- need balance report onsite- drip leg on furnace and unit heater- seal gas line and lineset penterations weather tight outside
Final2/6/20192/6/20192/6/2019PNH
DetailsBrian Scoles
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- no access
Rough-in10/9/201810/10/201810/10/2018PPASS
DetailsBrian Scoles
Reinspect Inspection requested via web by Brandon Sorensen- fireplace and hvac R/I ok
Pressure Test10/9/201810/10/201810/10/2018PPASS
DetailsBrian Scoles
Reinspect Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 60lb gas pass- tagged pipe by meter
Rough-in10/8/201810/9/201810/9/2018AFAIL
DetailsBrian Scoles
rough Phone #: ###-#### Inspection requested via web by Brandon Sorensen- ducting in crawl and ceiling needs insulated to pass R/I- need to install 2x4 in wall 2nd floor below wall exhaust fan- rest is good
Pressure Test10/8/201810/9/201810/9/2018AFAIL
DetailsBrian Scoles
pressure test Phone #: ###-#### Inspection requested via web by Brandon Sorensen- gauge at zero psi-
Rough-in10/3/201810/4/201810/4/2018ANR
DetailsBrian Scoles
rough in Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need to resubmit manual j showing system thats installed- doesnt match approved man j
Pressure Test10/3/201810/4/201810/4/2018AFAIL
DetailsBrian Scoles
pressure test Phone #: ###-#### Inspection requested via web by Brandon Sorensen- hard pipe needs to extend into fireplace- retest when complete