Permit Information
Permit NumberMEC18-04831
StatusFinaled
Name INTEGRITY HEATING & AIR
Site Address 8742 W NORTHVIEW ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Install new complete HVAC in new construction residential duplex with gas piping. Two units.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/28/20192/28/20192/28/2019APASS
DetailsBrian Scoles
final ok
Conference2/27/20192/28/20192/28/2019APASS
DetailsBrian Scoles
duct blast witness at 11 am- ###-####- final ok- duct blast test pass both units
Rough-in2/27/20192/27/20192/27/2019PCANC
DetailsBrian Scoles
blast test // Lakota Phone #: ###-####- rescheduled for tomorrow at 11 am per phone call with Brian
Final2/22/20192/25/20192/25/2019AFAIL
DetailsBrian Scoles
Doris- ###-####- need to witness duct blast test both units- need approved manual j onsite- need air balance report- need to support fluing in garage- condenser for one unit needs completed not set and uv protection on line set- need to fix all rips and tears in arma flex in garage both units-
Final2/22/20192/22/20192/22/2019PFAIL
DetailsBrian Scoles
Doris Phone #: ###-####- no access- needs garage codes or home needs to be unlocked
Rough-in11/21/201811/21/201811/21/2018PPASS
DetailsBrian Scoles
Locoda Phone #: ###-####- R/I ok both units
Rough-in11/19/201811/20/201811/20/2018PFAIL
DetailsBrian Scoles
Doris Ann Phone #: ###-####- range ducting both units still not addressed- talk to Terek about this by phone- got a plan to fix
Pressure Test11/19/201811/20/201811/20/2018PCANC
DetailsBrian Scoles
Doris Ann Phone #: ###-####- both units have passed pressure test
Rough-in11/8/201811/9/201811/9/2018AFAIL
DetailsBrian Scoles
toe kick is connect to the fantech , crawl space // Dorthy Phone #: ###-####- corrections still not addressed on range ducting- remove oval 90 degree and 6" 90 thats smashed at ceiling and reroute both units
Rough-in11/6/201811/6/201811/6/2018PFAIL
DetailsBrian Scoles
Dorthy Phone #: ###-####- range hood ducting correction not made (IRC 1503.1)- remove crimped oval 90 degree and smashed 6" 90 degree and reroute both units- reinspection fee issued
Pressure Test11/6/201811/6/201811/6/2018PCANC
DetailsBrian Scoles
Dorthy Phone #: ###-####- already passed
Rough-in10/17/201810/18/201810/18/2018AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Terek Worley- corrections still need to be made on fresh air and range ducting
Pressure Test10/17/201810/18/201810/18/2018ACANC
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Terek Worley- already passed
Rough-in10/10/201810/10/201810/10/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- 6" frersh air can not come from return air can (both units)- range hood duct needs to be smooth wall (IRC M1503.1) interior surface- need to seal R/A plenum boxes in garage by final (both units)
Pressure Test10/10/201810/10/201810/10/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass both units