Final | 2/6/2019 | 2/6/2019 | 2/6/2019 | P | PASS |
Jack Reynolds
|
|
|
les Phone #: ###-#### - final ok
|
Final | 2/4/2019 | 2/5/2019 | 2/5/2019 | A | FAIL |
Jack Reynolds
|
|
|
Les Phone #: ###-#### - need to pipe both furnace and tankless water heater combustion air to equipment
|
Final | 1/23/2019 | 1/23/2019 | 1/23/2019 | P | FAIL |
Jack Reynolds
|
|
|
Call 2089064067 when you arrive so we can tell you how to find the key to access the house. Home is vacant. Phone #: ###-#### Inspection requested via web by Les Gargan - gas line at furnace needs a sediment trap after shut off valve -secondary drain needs a wet switch installed. it cant be ran into the pump for the primary drain - A/C needs 20 amp fuses installed at service disconnect - I also noticed a new gas fireplace was installed and vented most likely by another contractor which wasnt permited. fireplace installers need to pull a permit before this mech permit can be finaled
|
Rough-in | 10/18/2018 | 10/19/2018 | 10/19/2018 | A | PASS |
Jack Reynolds
|
|
|
This is a reinspection. Of the roughin and pressure test. Phone #: ###-#### Inspection requested via web by Les Gargan -29lb gas pressure test ok- 5ln flue pressure test ok-R/I ok
|
Rough-in | 10/17/2018 | 10/18/2018 | 10/18/2018 | A | FAIL |
Jack Reynolds
|
|
|
Les Phone #: ###-####- inert tape on gas line penetration exterior wall- toe kick in bathroom needs to be ducted completely out of cabinet- flex gas line in crawl space needs supported where it meets rigid pipe- flex gas line in wall needs approved protection sheild at bottom plate - need to see a pressure test on complete piping system
|
Pressure Test | 10/17/2018 | 10/18/2018 | 10/18/2018 | A | PART |
Jack Reynolds
|
|
|
Les Phone #: ###-####- 5lb flue tests ok- partial 20lb gas pressure test ok- need to see the rest of the gas piping on a 20lb test
|