Permit Information
Permit NumberMEC18-04856
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 4661 N SUNDERLAND LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/12/201812/12/201812/12/2018PPASS
DetailsBrian Scoles
MEC AND FIREPL GARage CODE 7373 Phone #: ###-#### Inspection requested via web by Oleg Chervak
Final12/11/201812/11/201812/11/2018PFAIL
DetailsBrian Scoles
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- needs combustion air registers cut in doors in garage- no air balance they were finishing
Rough-in10/9/201810/9/201810/9/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- Hvac R/I ok
Rough-in10/9/201810/9/201810/9/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace R/I ok
Rough-in10/8/201810/9/201810/9/2018AFAIL
DetailsBrian Scoles
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- insulation shield on water heater b vent needs to extend to roof pitch- crawl needs completed- need to seal dryer duct to termination box- R/A for bedroom 2 & 3 not per man j needs to tie into 18" round ducting not at register can off 14" round- reinspection fee issued for ongoing issues on new construction R/Is- left correction notice front entry window
Pressure Test10/8/201810/9/201810/9/2018APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass