Permit NumberMEC18-05050
StatusFinaled
Name ICON AIR
Site Address 3143 S LINDA VISTA AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: HVAC Installation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/19/201812/20/201812/20/2018APASS
DetailsBrian Scoles
re final
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
Final12/14/201812/17/201812/17/2018PFAIL
DetailsBrian Scoles
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need access into house all doors locked up garage code worked- need 3 screws in water heater flue to china cap in garage- need to seal lineset penetration outside at a/c location-
Conference10/23/201810/24/201810/24/2018APASS
DetailsBrian Scoles
Witness blast 1130. I will make sure my guys have a ladder Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass
Rough-in10/24/201810/24/201810/24/2018APASS
DetailsBrian Scoles
Witness blast 1130. I will make sure my guys have a ladder Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
Rough-in10/23/201810/23/201810/23/2018PFAIL
DetailsBrian Scoles
Rough and pressure Phone #: ###-#### Inspection requested via web by Randy Hart- still need city approved manual J onsite to do inspection- send one with duct blast guys thats scheduled for tomorrow
Pressure Test10/23/201810/23/201810/23/2018PPASS
DetailsBrian Scoles
Rough and pressure Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass
Rough-in10/19/201810/22/201810/22/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved manual J onsite- need nail plates on primary pvc drain- all register boots need sealed with mastic on inside- exhaust fan connections need sealec to fan- all rips and tears inarma flex need fixed bare copper showing 2nd floor at ceiling
Pressure Test10/19/201810/22/201810/22/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- gauge under 20psi