Information based on query as of Monday, July 22, 2024.
Permit Information
Permit NumberMEC18-05653
StatusFinaled
Name TML LLC
Site Address 2121 N COLE RD
Project Name 
Customer Number22548-13
ePlanReviewNo
Description
New: HVAC
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/19/20196/20/20196/20/2019APASS
DetailsBrian Scoles
Final inspection ; Jake is your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams- final ok- card signed
Rough-in4/23/20194/24/20194/24/2019APASS
DetailsBrian Scoles
grid in the locker rooms for approval for cover ; Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- R/I o9k- ok for ceiling tiles
Rough-in4/22/20194/23/20194/23/2019AFAIL
DetailsBrian Scoles
Approval for cover on the locker room area. Jake is your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams- need to finish insulation tape seams in main corridor- all joints not done
Rough-in3/21/20193/21/20193/21/2019APART
DetailsBrian Scoles
Final inspection kitchen ; hood Phone #: ###-#### Inspection requested via web by Kim Adams- TCO for caffateria and kitchen only ok
Final3/19/20193/20/20193/20/2019PPART
DetailsBrian Scoles
the kitchen and cafeteria - Jake is your contact. Thank you Phone #: ###-#### Inspection requested via web by Kim Adams- all equipment under class 1 hoods needs to be set into place with clearances required- caffeteria, kitchen and roof ok- airbalance report ok-
Final3/13/20193/14/20193/14/2019APART
DetailsBrian Scoles
I need a final, temp c of o in the kitchen and rough in inspection in the locker rooms. Jake is your contact.
Thanks
Phone #: ###-#### Inspection requested via web by Kim Adams- need to extend flues on 2 units on roof 3 feet above intake- need 1500 degree gasket on both class 1hood exhaust fans- need to pan off 2 transfers above ceiling to kitchen- need all equipment set under both class 1 hoods and class 2 hood needs dishwasher installed in center- need air balance report for both class 1 hoods and 1 class 2 hood and MAU- R/I in locker rooms ok- ok to cover- 2 ceiling heaters NW entry ok- storage room in kitchen area ok to cover
Rough-in2/28/20193/1/20193/1/2019APART
DetailsBrian Scoles
RI inspection for ceiling cover in the kitchen at fairmont for tomorrow.
Contact Jake Johnstone ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty- ceiling grid in kitchen area and bathrooms ok- need to see storage room in kitchen when grid is installed- class 1 hood and class 2 hoods ok- ok for ceiling tiles excluding storage room
Rough-in2/22/20192/25/20192/25/2019APART
DetailsBrian Scoles
locker rooms for approval for duct wrap. Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- locker rooms seal on duct ok- ok for insulation- call in dishwasher hood when installed
Final2/21/20192/22/20192/22/2019ACANC
DetailsBrian Scoles
final inspection in the kitchen hood . Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- should have been R/I inspection
Rough-in2/22/20192/22/20192/22/2019APASS
DetailsBrian Scoles
final inspection in the kitchen hood . Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- fire wrap both drops and pants to hood ok- insulation all duct kitchen area ok- ok for grid kitchen area only
Rough-in2/13/20192/14/20192/14/2019APASS
DetailsBrian Scoles
Rough in for kitchen hood. Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- north and south grease ducts ok for firewrap- will need remaining R/I inspections scheduled when ready
Rough-in2/12/20192/13/20192/13/2019APART
DetailsBrian Scoles
Inspection of weld for kitchen hood. Jake is your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams- north grease duct welds in 4 locations ok- south grease duct missing welds east side above pants rest is good- rerschedule when ready
Rough-in2/4/20192/5/20192/5/2019APART
DetailsBrian Scoles
for ceiling cover inspection in the kitchen/ bathroom hard lids Phone #: ###-#### Inspection requested via web by Kim Adams- insulation on supply, return and make up air in kitchen only ok- all hard lid ceilings for bathrooms and kitchen area only ok to cover- still need light test on grease duct called in when ready
Rough-in1/30/20191/31/20191/31/2019APASS
DetailsChad Schwendiman
Grease duct light inspection at TML shop 120 E 40th street Steve Beason is the contact ###-#### Phone #: ###-#### Inspection requested via web by Dan Flaherty - Light test pass for 2 ea. straight drops, and 2 ea. pair of duct pants
Rough-in1/28/20191/29/20191/29/2019APART
DetailsBrian Scoles
Kitchen for duct wrap. Jake is your contact. Thank you Phone #: ###-#### Inspection requested via web by Kim Adams- seal on duct in kichen area supply return and make up ok- ok to insulate