Permit NumberMEC18-05804
StatusExpired
Name ALL TEMP HEATING & COOLING
Site Address 5506 W EDSON ST
Project Name 
Customer Number2822225-28
ePlanReviewNo
Description
Alteration or Repair: Replacing 80% furnace, A/C, and coil.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Mec-Aging Inspection10/15/201910/15/201910/15/2019 PASS
DetailsJack Reynolds
Doc Permit Expired ok
DOC - Permit Expired10/15/201910/15/201910/15/2019APASS
DetailsJack Reynolds
Doc Permit Expired ok permit hasn't been active since 12-19-18 when it failed a final inspection.
Mec-Aging Inspection7/16/20197/16/20197/16/2019 DONE
DetailsJack Reynolds
Called All Temp and left a message about their mechanical aging permit. If corrections have been made schedule inspection with homeowner. Permit will expire at next mechanical aging inspection if not active
Final12/17/201812/19/201812/19/2018AFAIL
DetailsJack Reynolds
If possible please call Lori at ###-#### one hour before. Thank you. Phone #: ###-#### Inspection requested via web by James Cox
-A/C breaker size needs to be a 25 amp
- need approved furnace disconnect
- secondary drain needs a wet switch right now its draining on carpet
- single wall pipe needs 6" clearances/ reduction methods applied or b vent installed
Final12/11/201812/14/201812/14/2018ANH
DetailsJack Reynolds
If possible, please call Lori one hour before at ###-####. Thank you. Phone #: ###-#### Inspection requested via web by James Cox
- No access to home called number in notes and no anwser left notice on front door