Final | 12/21/2018 | 12/21/2018 | 12/21/2018 | P | PASS |
Jack Reynolds
|
|
|
if questions call Jared @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann - 20lb gas pressure test ok - final ok
|
Final | 12/19/2018 | 12/20/2018 | 12/20/2018 | A | FAIL |
Jack Reynolds
|
|
|
if questions call Jared @ ###-#### or Jerry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - pressure gauge was under 20lb - need to see two shut off valves with a tee between the two valves on a live gas line or disconnect new gas line from live gas line for pressure test
|
Pressure Test | 12/20/2018 | 12/20/2018 | 12/20/2018 | A | FAIL |
Jack Reynolds
|
|
|
if questions call Jared @ ###-#### or Jerry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - 20lb gas pressure test fail gauge was under 20 lb - need to see two shut off valves with an open tee between the two valves when connected to live gas line
|
Final | 12/17/2018 | 12/18/2018 | 12/18/2018 | P | FAIL |
Jack Reynolds
|
|
|
if questions call Jared @ ###-#### or Jerry @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann - 20lb gas pressure test fail gauge was stuck at 12lbs- need to see gas flex supported in crawl -
|