DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/21/20193/27/20193/27/2019APASS
DetailsChad Schwendiman
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart
Conference2/14/20192/14/20192/14/2019PPASS
DetailsBrian Scoles
duct blast test at 100pm- duct blast test pass
Conference2/13/20192/14/20192/14/2019ACANC
DetailsBrian Scoles
confirmed Intentness blast scheduled in with Brian @11:30AM Phone #: ###-#### Inspection requested via web by Randy Hart- started on pm house inspection- i reschedule for pm
Rough-in2/6/20192/7/20192/7/2019PPASS
DetailsBrian Scoles
re inspection
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- HVAC R/I ok- fireplace R/I ok
Rough-in2/5/20192/6/20192/6/2019AFAIL
DetailsBrian Scoles
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace flue draft stop needs minimum 1" clearance to combustibles at attic location- all exhaust fans needs sealed plastic to metal fittings(still ongoing issue)- gas line in attic needs supported /secured to structure every 10 feet to fireplace- left correction notice front entry window- furnace and coil match manual j in attic
Pressure Test2/5/20192/6/20192/6/2019APASS
DetailsBrian Scoles
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass- tagged meter location
Pressure Test1/2/20191/4/20191/3/2019ACANC
DetailsChad Schwendiman
code 2468 Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Rough-in1/2/20191/4/20191/3/2019ACANC
DetailsChad Schwendiman
code 2468 Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart