Final | 3/12/2019 | 3/19/2019 | 3/19/2019 | A | PASS |
Jack Reynolds
|
|
|
Please inspect in the later AM and call on way: Jeff ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace ac coil co ok
|
Final | 2/21/2019 | 2/22/2019 | 2/22/2019 | P | FAIL |
Jack Reynolds
|
|
|
Please call on way: Maddie ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - line set needs insulation finished at A/C and penetration sealed - txv at indoor coil needs insulated - condensate line for 90% was ran outside and didnt have proper slope. run condensate line to indoor location to prevent freezing
|
Pressure Test | 2/21/2019 | 2/22/2019 | 2/22/2019 | P | PASS |
Jack Reynolds
|
|
|
Please call on way: Maddie ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 5lb flue pressure test ok
|
Final | 2/20/2019 | 2/21/2019 | 2/21/2019 | P | CANC |
Jack Reynolds
|
|
|
Please call Maddie when you are on the way - ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|
Pressure Test | 2/20/2019 | 2/21/2019 | 2/21/2019 | P | CANC |
Jack Reynolds
|
|
|
Flue pressure test. Please call Maddie when you are on the way - ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|