Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberMEC19-01068
StatusFinaled
Name LEGENDS MECHANICAL LLC
Site Address 2739 N CARMEN AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: complete hvac install
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/19/20196/20/20196/20/2019APASS
DetailsBrian Scoles
Meeting Jay for confirmation @ 9am. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
Conference6/19/20196/19/20196/19/2019PPASS
DetailsBrian Scoles
duct blast test pass
Rough-in4/3/20194/3/20194/3/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
Rough-in4/2/20194/3/20194/3/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- need nail plate 2nd floor flor and ceiling on pvc flue- need to insulate outside air in joist in garage- duct in crawl laying on ground needs supportted to minimum 4" off ground- left notice on furnace
Pressure Test4/2/20194/3/20194/3/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location- 5lb flue pass
Rough-in3/28/20193/29/20193/29/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- fresh concrete pour in garage no access to furnace or man j- outside air in garage needs insulated to R-8- reschedule when access is ok
Pressure Test3/28/20193/29/20193/29/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Gary Reeves- fres concrete pour in garage- no access