Mec-Aging Inspection | 4/15/2020 | 4/15/2020 | 4/15/2020 | | PASS |
Jack Reynolds
|
|
|
Doc Permit Expired ok
|
DOC - Permit Expired | 4/15/2020 | 4/15/2020 | 4/15/2020 | A | PASS |
Jack Reynolds
|
|
|
Doc Permit Expired ok permit not active
|
Mec-Aging Inspection | 1/15/2020 | 1/15/2020 | 1/15/2020 | | DONE |
Jack Reynolds
|
|
|
Talked with Steve from Diamond Heating about their mechanical aging permit. Contractor has attemped to contract homeowner with no success. Permit will expire at next mechanical aging inspection if not active.
|
Mec-Aging Inspection | 10/16/2019 | 10/16/2019 | 10/16/2019 | | DONE |
Jack Reynolds
|
|
|
WIP
|
Final | 7/17/2019 | 7/18/2019 | 7/18/2019 | P | FAIL |
Jack Reynolds
|
|
|
Phone #: ###-#### Inspection requested via web by Adam Eickmeier - need to see 5lb flue pressure test on water heater flue that was moved - also will need to see installation instructions for water heater
|
Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 | A | PASS |
Jack Reynolds
|
|
|
Johnny Phone #: ###-#### - R/I ok - will need to see a 5lb flue test on existing water heater flue that was moved by final
|
Rough-in | 3/20/2019 | 3/21/2019 | 3/21/2019 | A | NR |
Jack Reynolds
|
|
|
PLEASE CALL OUR LEAD INSTALLER SAM WHEN 30-45 MINS IN ROUTE SO WE HAVE HAVE FLUE UNDER PRESSURE FOR YOU WHEN YOU ARRIVE. CORRECTIONS TO MAN J MADE AND APPROVED BY TROY JAMES AND THAT COPY OF MAN J HAS BEEN REPLACED AND LOCATED ONSITE FOR YOU. Phone #: ###-#### Inspection requested via web by Rick Montgomery - tried calling Sam and left a voicemail. showed up onsite and no access
|
Rough-in | 3/18/2019 | 3/19/2019 | 3/19/2019 | P | FAIL |
Chad Schwendiman
|
|
|
PLEASE CALL OUR LEAD INSTALLER SAM WHEN IN ROUTE. CLIENT IS WANTING TO MOVE TO NEXT STAGE WITH SHEETROCK AND WE ARE READY FOR ROUGH INSPECTION PLEASE. Phone #: ###-#### Inspection requested via web by Rick Montgomery - 1) Need to pressure test pvc flue 2) Equipment installed doesn't match the approved manual J 3) Missing 8" supply in kitchen 4) Supply branch lines feeding the main level are not sized per the approved manual J. Manual J shows 8" they were ran in 7"
|