Permit Information
Permit NumberMEC19-01122
StatusExpired
Name EASY HEATING & AIR
Site Address 5932 W POPLAR DR
Project Name 
Customer Number2474006
ePlanReviewNo
Description
Alteration or Repair: Relocate furnace. Run new gas line.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Mec-Aging Inspection1/10/20201/10/20201/10/2020 DONE
DetailsBrian Scoles
DOC - Permit Expired1/10/20201/10/20201/10/2020APASS
DetailsBrian Scoles
no calls- no activity- permit expired
Mec-Aging Inspection10/11/201910/11/201910/11/2019 CANC
DetailsChad Schwendiman
Called and talked to contractor. They are going to look into this and get it scheduled
Final3/19/20193/22/20193/22/2019AFAIL
DetailsBrian Scoles
Any time, morning or afternoon, should be fine. Thank you! Phone #: ###-#### Inspection requested via web by kelly Martin- need to seal off gas line penetration at meter weather/rodent proof- b vent needs 1" clearance to combustibles ie insulation, wiring and at roof- sheet rock needs installed where b vent is and an insulation shield installed- need to provide co detectors by bedrooms
Pressure Test3/20/20193/21/20193/21/2019APASS
DetailsBrian Scoles
Tony, or call Alyssa ###-#### Phone #: ###-####- 20lb gas pass from meter to furnace location in garage
Pressure Test3/19/20193/20/20193/20/2019PNR
DetailsBrian Scoles
Any time, morning or afternoon, should be fine. Thank you! Phone #: ###-#### Inspection requested via web by kelly Martin- installer said no gas was run at this time- reschedule when ready