Final | 6/6/2019 | 6/7/2019 | 6/7/2019 | A | PASS |
Jack Reynolds
|
|
|
Lock box code 2485 Box is on the electric meter in the back of the house. The house in not occupied only staged. Phone #: ###-#### Inspection requested via web by Tony Fogg - final ok
|
Final | 6/5/2019 | 6/6/2019 | 6/6/2019 | A | FAIL |
Jack Reynolds
|
|
|
Lock box by electric meter in rear of house. Code 2485. The box has to many keys in it so press the cover and pull firmly on the latch. The house is not occupied only staged. Phone #: ###-#### Inspection requested via web by Tony Fogg - gas line at furnace needs a sediment trap installed - secondary drain for furnace coil needs ran down to garage floor - condensate pump needs safety switch wired to shut down in case of a fault
|
Rough-in | 3/20/2019 | 3/21/2019 | 3/21/2019 | A | PASS |
Jack Reynolds
|
|
|
Lock box code 2485 Phone #: ###-#### Inspection requested via web by Tony Fogg - R/I ok - Make sure range duct has backdraft damper
|