Permit Information
Permit NumberMEC19-02033
StatusFinaled
Name THE COMFORT SOURCE
Site Address 2018 W CHERRY LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Rough In
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/2/20198/5/20198/5/2019APASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Lynn Johnston
- final ok
Final8/1/20198/1/20198/1/2019PPART
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Lynn Johnston
- need to see condensate line for high wall unit finished
Rough-in5/22/20195/23/20195/23/2019APASS
DetailsJack Reynolds
pressure test Inspection requested via web by Lynn Johnston
- R/I ok
- at final need to check high wall condensate drain being tie into plumbing in crawl
Pressure Test5/23/20195/23/20195/23/2019APASS
DetailsJack Reynolds
pressure test Inspection requested via web by Lynn Johnston
- 20lb gas pressure test ok
- tagged meter location
Rough-in5/21/20195/22/20195/22/2019PFAIL
DetailsJack Reynolds
pressure test Inspection requested via web by Lynn Johnston
- 20lb gas pressure test fail
-gas line penetration needs to be wrapped with 10 mill tape
- condensate line for high wall unit needs finished in the crawl
Pressure Test5/22/20195/22/20195/22/2019PFAIL
DetailsJack Reynolds
pressure test Inspection requested via web by Lynn Johnston
- gas pressure gauge needs to be a 30lb gauge set at 20lb