Permit Information
Permit NumberMEC19-02082
StatusFinaled
Name ICON AIR
Site Address 9717 W ROAN MEADOWS DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Installing HVAC and Fireplace
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/1/20197/5/20197/5/2019APASS
DetailsChad Schwendiman
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart
Rough-in5/23/20195/24/20195/24/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace and HVAC R/I ok
Pressure Test5/23/20195/24/20195/24/2019APASS
DetailsBrian Scoles
Inspection requested via web by Randy Hart- 20lb gas pass
Rough-in5/22/20195/23/20195/23/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart
1- gas test failed at 13psi
2- need to insulate bare metal on supply plenums where round ties into square duct and all wye branch fittings in attic where bare metal showing to R-8
3- supply main to master bedroom needs 3 inch clearance to fireplace flue in attic
4- need ladder provided by contractor to access furnace/coil in attic
5- need to insulate filter box for outside air in attic where ties onto return plenum bare meatal showing
6- master bath exhaust in toilet room needs metal to plactic connection sealed at fan location

left correction notice front entry window
Pressure Test5/22/20195/23/20195/23/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- gas test failed gauge at 13psi
Pressure Test5/21/20195/22/20195/22/2019ANR
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Randy Hart
Rough-in5/21/20195/22/20195/22/2019ANR
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Randy Hart