Final | 8/16/2019 | 8/16/2019 | 8/16/2019 | P | PASS |
Brian Scoles
|
|
|
John Phone #: ###-####- HVAC and fireplace final ok
|
Final | 8/14/2019 | 8/15/2019 | 8/15/2019 | P | FAIL |
Brian Scoles
|
|
|
Garage code 6074 Phone #: ###-#### Inspection requested via web by Jon VanderStelt 1- need to uv protect line set outside 2- single all flue on water heater needs 6" clearance to combustibles 3- need to fill out all totals on air balance form for tests done and design
|
Rough-in | 6/18/2019 | 6/18/2019 | 6/18/2019 | P | PASS |
Brian Scoles
|
|
|
fireplace rough in Phone #: ###-#### Inspection requested via web by Jon VanderStelt- HVAC and fireplace R/I ok
|
Pressure Test | 6/18/2019 | 6/18/2019 | 6/18/2019 | P | PASS |
Brian Scoles
|
|
|
floor register placement is due to floor joist in the way, and builder preference for alternate location Phone #: ###-#### Inspection requested via web by Jon VanderStelt- 20lb gas pass tagged meter location
|
Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 | P | NR |
Brian Scoles
|
|
|
John Phone #: ###-####- crawl needs completed- bedroom has supply right at entry of door instead of being under window is there a reason not where indicted on man J- need to fix all rips and tears in arma flex bare copper showing- needs register can installed for transfer in hallway to bedrooms or pan off wood with metal, wood not exceptable material for ducting
|
Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 | P | NR |
Brian Scoles
|
|
|
John- this for the fire place rough-in Phone #: ###-####- need installation insrtuction accessible behind glass- flexible flue doesnt have 1" clearance to combustibles at roof touching plywood-
|
Pressure Test | 6/17/2019 | 6/17/2019 | 6/17/2019 | P | FAIL |
Brian Scoles
|
|
|
John Phone #: ###-####- gauge wont zero out
|