Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberMEC19-02496
StatusFinaled
Name HUGHES RONALD P
Site Address 11364 W PECONIC DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Added gas lines throughout the house for appliances//Melinda Hughes added- 2 bath exhaust, 1 dreyer exhaust and 1 vent for water heater on 6-13-19 JA1 6/21/19-removed fireplace-different company to do that CAN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/18/201910/18/201910/18/2019ACANC
DetailsBrian Scoles
final ok
DOC - Permit Finaled10/18/201910/18/201910/18/2019APASS
DetailsBrian Scoles
Final10/14/201910/15/201910/15/2019PPART
DetailsBrian Scoles
Contact Ron Hughes when on your way please ###-#### Inspection requested via web by Melinda Hughes- need clarification on b vent ran above electrical panel- electrical inspector will let homeowner know on his inspection- rest is good
Conference8/22/20198/23/20198/23/2019ADONE
DetailsBrian Scoles
Gas Fireplace stone framing consult. Melinda Hughes ###-#### Phone #: ###-#### Inspection requested via web by Melinda Hughes- other mech contractor will pull permit for fireplace and its ok to install hardy board over existing opening per fireplace company- will need fireplace inspection completed before any rock/stone can be installed- ok for hardy board
Rough-in6/21/20196/24/20196/24/2019PPASS
DetailsBrian Scoles
Melinda (wife) Phone #: ###-####- R/I ok- fireplace by contractor will need permit pulled and inspected
Pressure Test6/17/20196/17/20196/17/2019APASS
DetailsBrian Scoles
20lb gas pass whole system- tagged meter location- 5lb flue pass
Conference6/13/20196/17/20196/17/2019PDONE
DetailsBrian Scoles
can you call when you are on your way please. conference and pressure test. Phone #: ###-#### Inspection requested via web by Melinda Hughes
1- dryer duct needs firred out
2- support gas piping per csst gas piping installation instructions in attic
3- insulation shield needs 1" clearance to combustibles
4- b vent needs 1" clearance to combustibles floor and ceiling and b vent in furnace closet can not run over the electrical box
5- range ducting and location ?
6- combustion aior for furnace closet 1 high and 1 low
7 exhaust fans vented to outside

went over onsite with homeowner Melinda

call in R/I inspection when ready
Pressure Test6/12/20196/13/20196/13/2019PFAIL
DetailsBrian Scoles
please call or text when headed to house to meet inspector. Phone #: ###-#### Inspection requested via web by Melinda Hughes- 20lb test requires max 30 lb gauge