Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberMEC19-02601
StatusFinaled
Name ELITE SYSTEMS
Site Address 1940 S EAGLESON RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: new house new construction gas furnace and ac
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/28/20198/30/20198/30/2019APASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Kim Evans-call for access code
- final ok
Rough-in6/27/20196/28/20196/28/2019APASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Kim Evans
- R/I ok
Pressure Test6/21/20196/21/20196/21/2019APASS
DetailsChad Schwendiman
20lb gas pass
Rough-in6/20/20196/21/20196/21/2019AFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by Kim Evans - Need to complete the crawl, need to insulate metal supply trunk in the crawl
Rough-in6/18/20196/19/20196/19/2019AFAIL
DetailsJack Reynolds
It''s Open Phone #: ###-#### Inspection requested via web by Kim Evans
- Stamped Man J onsite
- 20lb gas pressure test fail
- water heater b vent needs 1" clearances
- range vent needs sealed
- finished crawl space( duct work, dryer vent
- line set needs supported in attic
- line set and dryer vent needs nail plates
- line set insulation needs rips fixed
- supply trunk in crawl needs insulated
- system needs fresh air installed