Final | 2/10/2020 | 2/10/2020 | 2/10/2020 | P | PASS |
Eric Strole
|
|
|
Dale Phone #: ###-####
|
Mec-Aging Inspection | 1/21/2020 | 1/21/2020 | 1/21/2020 | | CANC |
Chad Schwendiman
|
|
|
wip
|
Rough-in | 7/8/2019 | 7/9/2019 | 7/9/2019 | A | PASS |
Ben Livingston
|
|
|
DALE Phone #: ###-####
|
Pressure Test | 7/9/2019 | 7/9/2019 | 7/9/2019 | P | PASS |
Ben Livingston
|
|
|
DALE Phone #: ###-#### 60lb 5lb flue x3
|
Rough-in | 7/3/2019 | 7/5/2019 | 7/5/2019 | P | FAIL |
Ben Livingston
|
|
|
Dale Phone #: ###-#### --5 lb flue x3 okay-- need makeup air for range if over 400cfm, some exhaust duct needs hangers, place a permanent sticker in each dryer box showing length of dryer vents
|
Rough-in | 7/2/2019 | 7/3/2019 | 7/3/2019 | A | NR |
Jack Reynolds
|
|
|
gas line Phone #: ###-####
|
Pressure Test | 7/3/2019 | 7/3/2019 | 7/3/2019 | A | FAIL |
Jack Reynolds
|
|
|
gas line Phone #: ###-#### - 5lb flue pressure test on roof fail - 60lb gas pressure test ok - tagged meter location 2- 5lb flue pressure tests one tankless water heater and one a furnace terminating on east side of house
|