Final | 8/9/2019 | 8/9/2019 | 8/9/2019 | P | PASS |
Jack Reynolds
|
|
|
PLEASE CALL CONTRACTOR JEFF @ # LISTED WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - R/I ok
|
Rough-in | 7/29/2019 | 7/29/2019 | 7/29/2019 | P | FAIL |
Jack Reynolds
|
|
|
PLEASE CALL APPRENTICE JAMIE WHEN EN ROUTE FOR ROUGH-IN INSPECTION Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - need to see energy star rated fan installed in bathroom for continuous operation
|
Pressure Test | 7/29/2019 | 7/29/2019 | 7/29/2019 | P | PASS |
Jack Reynolds
|
|
|
PLEASE CALL APPRENTICE JAMIE WHEN EN ROUTE FOR ROUGH-IN INSPECTION Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - 20lb gas pressure test ok - tagged meter location
|
Final | 7/22/2019 | 7/23/2019 | 7/23/2019 | A | CANC |
Jack Reynolds
|
|
|
PLEASE CALL CONTRACTOR DARREN @ # LISTED WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - should have been a R/I inspection
|
Rough-in | 7/23/2019 | 7/23/2019 | 7/23/2019 | A | FAIL |
Jack Reynolds
|
|
|
PLEASE CALL CONTRACTOR DARREN @ # LISTED WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - 1 line set needs nail plates installed at top of wall both sides - condensate line in crawl needs supported - need to see gas pressure test - range vent needs sealed - need to see mechanical ventialtion installed using an engery star exhaust fan operating continuously ( this can be installed in the laundry room with a transfer grille installed to the open area)
|