Permit Information
Permit NumberMEC19-03593
StatusFinaled
Name WESTERN HEATING & A/C
Site Address 1605 S COLORADO AVE
Project NameDuplex to SFD conversion
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: new system for remodeled home. furnace in attic. stripped to studs so heat should not be an issue. over head supplies to main floor and three supply risers to basement.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/9/201912/11/201912/11/2019APASS
DetailsJack Reynolds
LOCK BOX CODE 7432 Phone #: ###-#### Inspection requested via web by Aaron Alandt
- final ok
Final12/6/201912/9/201912/9/2019AFAIL
DetailsJack Reynolds
LOCK BOX 7432 Phone #: ###-#### Inspection requested via web by Aaron Alandt
- need to see Duct Blast test
- line set in wall of laundry room needs insulation re installed
- gas line penetration needs sealed
Rough-in10/7/201910/7/201910/7/2019PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- R/I ok
Pressure Test10/7/201910/7/201910/7/2019PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 5lb flue pressure test ok
Pressure Test10/3/201910/4/201910/4/2019AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 5lb flue fail under 5lb
Rough-in10/3/201910/4/201910/4/2019AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 5lb flue pressure test under 5lb
Rough-in10/2/201910/2/201910/2/2019AFAIL
DetailsJack Reynolds
lock box code 7432 Phone #: ###-#### Inspection requested via web by Aaron Alandt
- water heater flue needs ran in solid core PVC and re tested
Pressure Test10/2/201910/2/201910/2/2019AFAIL
DetailsJack Reynolds
lock box code 7432 Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 20lb gas pressure test ok
- tagged meter location
- flue for water heater needs to be ran in solid core PVC not cell core PVC and re tested