Permit Information
Permit NumberMEC19-03978
StatusFinaled
Name INTEGRITY HEATING & AIR LLC
Site Address 11483 W ALDERSHOT DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Install new complete HVAC in new construction residential home with gas piping.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/7/20201/8/20201/8/2020APASS
DetailsBrian Scoles
Garage Code: 1234
If this does not work please contact Sam with Simplicity Homes ###-#### Phone #: ###-#### Inspection requested via web by Terek Worley- final ok
Final1/6/20201/6/20201/6/2020PFAIL
DetailsJack Reynolds
garage code 1234 Phone #: ###-#### Inspection requested via web by Terek Worley
- need locking caps installed on A/C
- one flue termination needs storm collar pulled down to roof flashing and re-sealed
Rough-in10/17/201910/18/201910/18/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- R/I ok
Rough-in10/15/201910/15/201910/15/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley-
1- need to remove 6" tap from R/A can and patch/seal and insulate to r-6
2- need to insulate outside air filter box to r-6 not r-4.2
3-need to fix all rips and tears in arma flex where bare copper can be seen in wall and attic

reinspection fee issued
Pressure Test10/15/201910/15/201910/15/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
Rough-in10/9/201910/10/201910/10/2019AFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Terek Worley
- return can and fresh air can need R6 ins. not R4.2 -
Pressure Test10/9/201910/10/201910/10/2019AFAIL
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by Terek Worley
- gauge still doesnt zero out -
Rough-in10/7/201910/8/201910/8/2019AFAIL
DetailsBrian Scoles
Please contact Project Manager Sam before inspection so that he can ensure a ladder is available (208)-###-#### Phone #: ###-#### Inspection requested via web by Terek Worley-
1- gas gauge wont zero out
2- need to remove 6" tap from R/A can and patch and insulate
3- need to insulate outside air filter box to minimum R-6
4- need to fix rips and tears in arma flex where bare copper can be seen in wall and attic

left notice front window
Pressure Test10/7/201910/8/201910/8/2019AFAIL
DetailsBrian Scoles
Please contact Project Manager Sam before inspection so that he can ensure a ladder is available (208)-###-#### Phone #: ###-#### Inspection requested via web by Terek Worley- gauge wont zero out
Rough-in9/23/20199/23/20199/23/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley
1- need ladder provided by contractor to access furnace/coil in attic
2- outside air can not come from register can needs tied into R/A plenum near furnace
3- need to fix all rips and tears kin arma flex bare copper can bee seen
4- need city approved man j onsote
5- gas test fail gauge doesnt zero out
6- furnace flue in attic needs b vent 90 at furnace in attic

left notice front window
Pressure Test9/23/20199/23/20199/23/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Terek Worley- gas test fail gauge doesnt zero out